Actions

Difference between revisions of "IP Flush Master -V2 Board Connectors"

From Zenitel Wiki

(J11, J12 & J13 - Handset)
(S1 - Microphone Selection)
Line 34: Line 34:
 
* ''When the "Station Type" is set as '''CRM''' in AlphaPro, the inputs are mapped as '''251, 252''' and '''253'''.'' }}
 
* ''When the "Station Type" is set as '''CRM''' in AlphaPro, the inputs are mapped as '''251, 252''' and '''253'''.'' }}
  
====S1 - Microphone Selection====
+
 
Slide-switch to select internal microphone (Int) or gooseneck microphone (Ext).
 
[[File:IP Master Board 12.PNG|left|thumb|200px|S1]]
 
<br style="clear:both;" />
 
  
 
[[Category:Turbine Connections]]
 
[[Category:Turbine Connections]]

Revision as of 15:10, 23 June 2023

AEIS.png

This chapter gives details about connections and indications for:

IPFlushMasterKitPCB2.png

P1 - LAN port & P2 AUX port

P1:

LAN connector for 10/100 Mbit Ethernet connection. The station can be powered from this connection if the line supports Power over Ethernet (PoE).

The connector has two LEDs in front where the right (R) LED indicates Ethernet speed and the left (L) LED verifies Ethernet link and traffic. (L and R as seen from the connector side)

P2:

RJ45 connector for auxiliary equipment like IP camera, PC or a second IP station. This port does not have an individual IP address. It does not carry power for AUX equipment.

P1/P2


P4 - Inputs and Station LED

6-pin plug-on screw terminal for external connections.

P4


  • Pin 1/4 Input 1
  • Pin 2/4 Input 2
  • Pin 3/4 Input 3
  • Pin 5/6 Station LED for call message info.
Note icon
  • When "Station Type" is set as Master station in AlphaPro, the inputs are mapped as DAK 11, 12 and 13.
  • When the "Station Type" is set as CRM in AlphaPro, the inputs are mapped as 251, 252 and 253.