The IP Hotline comes with either the INCA IP Flush Master board, or the TKIS-2 kit inside.
+
The IP Hotline handset is using the Mic and Speaker connectors for audio.
==Turbine Based==
 
=== Introduction ===
 
[[File:1008070010 Hotline IP-TKIS.png|right|300px]]
 
The table below is an overview of the main connectors involved when installing the IP Hotline Station.
 
  
{| border="1"
+
I/O #1 is used as an input to detect the hook switch
|Ethernet/Power|| 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
 
|-
 
|Secondary Power || 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
 
|-
 
|Relays || There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
 
|-
 
|Input/Output || 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
 
|-
 
|Audio Line Out || A balanced 600 ohm audio line out with induction loop signal
 
|}
 
  
To access these connectors the front cover must be removed.
+
For more details see [[Turbine Compact series board connectors]]
  
 +
[[File:1008070010 Hotline IP-TKIS.png|500px]]
  
=== Power Supply ===
 
The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.
 
 
If PoE is not available, the IP Hotline Station  can be connected to a 24 VDC local power supply.
 
 
See Related Article [[TKIS Connections]] for local power supply connections.
 
 
=== Network Connection ===
 
There is one RJ-45 port on this IP Hotline Station that is used for PoE/LAN Ethernet connection:
 
:* LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
 
 
=== Input/Output Connections ===
 
There are 6 I/O connection options for the IP Hotline Station.
 
These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.
 
 
==== P2 - Relay Output and External Power Input ====
 
5-pin plug-on terminal for relay and external power
 
[[File:TCIS Connections 5.PNG|thumb|500px|left]]
 
<br style="clear:both;" />
 
:Pin 1/2:  24 VDC for external secondary power if PoE is not used. Pin 1 is positive.
 
:Pin 3: COM relay (Common)
 
:Pin 4: NO relay (Normally Open)
 
:Pin 5: NC relay (Normally Closed)
 
 
* Relay switching capacity: Max. 60 watt (Max voltage: 250VAC/220VDC. Max current: 2A)
 
* Connectable conductors:  0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
 
 
==== P3 - 10-pin plug-on terminal for I/O's and Audio Line Out ====
 
[[File:TCIS Connections 6.PNG|thumb|300px|left]]
 
 
:Pin 1  5.3V (max. 200mA current)
 
:Pin 2  GND
 
:Pin 3  Input for Hookswitch for handset cradle (and for restoring Factory Default Setting)
 
:Pin 4  Button Input or LED Driver
 
:Pin 5  Button Input or LED Driver
 
:Pin 6  Button Input or LED Driver
 
:Pin 7  Button Input or LED Driver
 
:Pin 8  Button Input or LED Driver
 
:Pin 9  600 ohm balanced line out +
 
:Pin 10  600 ohm balanced line out -
 
 
<br style="clear:both;" />
 
* Connectable conductors:  0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
 
 
==== P4 - Loudspeaker & Electret microphone ====
 
[[File:TCIS Connections 7.PNG|thumb|500px|left]]
 
<br style="clear:both;" />
 
:Pin 1: Speaker output +
 
:Pin 2: Speaker output -
 
:Pin 3:  Electret Microphone +
 
:Pin 4:  Electret Microphone -
 
 
* Connectable conductors:  0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
 
* Recommended loudspeaker impedance: 8 ohms
 
 
{{Note | To enable the electret microphone input when using a [[TKIS-2]], the "'''Product Model And Accessory'''" must be set to "'''Kit'''" under [[Main Settings (IP Stations)|Station Main > Main Settings]] in the web interface of the device.}}
 
 
For more details see [[Turbine Compact Board Connectors]].
 
 
==INCA Based==
 
=== Introduction ===
 
The table below is an overview of the main connectors involved when installing the IP Hotline Station.
 
 
{| border="1"
 
|-
 
| align=left | LAN (P1) || 10/100 Mbps RJ45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
 
|-
 
| align=left | AUX (P2) || 10/100 Mbps RJ45 port for auxilliary equipment such as PC or IP Camera.
 
|-
 
| align=left | Input/Output || Pluggable screw terminal
 
|-
 
| align=left | Local Power || Pluggable screw terminal, 17-27 VDC Idle 4W, max. 8W
 
|-
 
|}
 
 
To access these connectors the front cover must be removed.
 
 
[[File:IP Master Station Kit.PNG|right|300px]]
 
=== Power Supply ===
 
The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.
 
 
If PoE is not available, the IP Hotline Station  can be connected to a 24 VDC local power supply.
 
 
See Related Article [[INCA Master Station Kit Board Connectors]] for local power supply connections.
 
 
=== Network Connection ===
 
There are two RJ45 ports on this IP Hotline Station:
 
:* LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
 
:* AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera.
 
 
=== Input/Output Connections ===
 
There are I/O connection options for the IP Hotline Station. These I/O connections include:
 
 
==== P3 - External Loudspeaker, Relay Output and External Power Input ====
 
6-pin plug-on screw terminal for external connections.
 
[[File:IP Master Board 2.PNG|left|thumb|200px|P3]]
 
<br style="clear:both;" />
 
*Pin 1/2  Connection to the loudspeaker of the handset
 
*Pin 3/4  Internal NO relay contact for additional call indication etc.
 
*Pin 5/6  Connect 24 VDC for station power if PoE is not used. Pin 6 is positive.
 
 
==== P4 - Inputs and Station LED ====
 
6-pin plug-on screw terminal for external connections.
 
[[File:IP Master Board 3.PNG|left|thumb|200px|P4]]
 
<br style="clear:both;" />
 
*Pin 1/4  Input for Hookswitch for handset cradle (and for restoring Factory Default Setting)
 
*Pin 2/4  Input 2 (optional)
 
*Pin 3/4  Input 3 (optional)
 
*Pin 5/6  Station LED for call message info. (Pin 6 is positive.)
 
 
==== J10 - Microphone ====
 
Connection to handset microphone
 
[[File:IP Master Board 10.PNG|left|thumb|200px|J10]]
 
<br style="clear:both;" />
 
*Pin 1  MIC+
 
*Pin 2  MIC-
 
 
Note that the microphone selection switch next to connector J10 should be in the '''left position''', labeled "Int.".
 
 
 
For more details see [[INCA Substation Board Connectors]].
 
 
[[Category: INCA Connections]]
 
 
[[Category: Turbine Connections]]
 
[[Category: Turbine Connections]]

Latest revision as of 13:26, 23 June 2023

The IP Hotline handset is using the Mic and Speaker connectors for audio.

I/O #1 is used as an input to detect the hook switch

For more details see Turbine Compact series board connectors

1008070010 Hotline IP-TKIS.png