Actions

Difference between revisions of "IP Substation - Amplified calling"

From Zenitel Wiki

Line 17: Line 17:
 
* In [[Exchange_%26_System_%28AlphaPro%29#RCO|Exchange & System -> RCO]],  [[IP_Station_Configuration#RCO_-_Remote_Control_Output|map a free RCO to the relay]] of the station.
 
* In [[Exchange_%26_System_%28AlphaPro%29#RCO|Exchange & System -> RCO]],  [[IP_Station_Configuration#RCO_-_Remote_Control_Output|map a free RCO to the relay]] of the station.
 
* In Users & Stations select the IP station in the list box, and press the button 'Events'. 'Insert' a new events with the following attributes:
 
* In Users & Stations select the IP station in the list box, and press the button 'Events'. 'Insert' a new events with the following attributes:
 +
[[Image:IP substation RCO 10.png|thumb|IP substation]]
 
{|  
 
{|  
 
|-
 
|-

Revision as of 18:31, 28 November 2008

This article describes how to connect an external amplifier to the line output of the IP substation.

Power Amplifier 1000614100

Amplified calling - amplifier constantly on

Amplifier constanly on

The power amplifier is controlled through input 1 and 2. By strapping one can make the amplifier constanly on:

  • Strap point 2 and 3
  • Strap point 1 and 7

Note: When the amplifier is constanly on some humming might be heard in the speaker in idle.

Amplified calling - amplifier controlled by M-key

Amplifier controlled by relay

The amplifier can be switched on and off by the relay on the IP substation. The relay is controlled by the RCO in the Event Handler.

Configure the relay operation:

IP substation
Event Owner: The IP station
Event type: 1 - Audio
Subevent: 126 (Press 'Details' to see which audio events)
When change to: ON or OFF
When related to: (not used)
Action: RCO 10