Difference between revisions of "IP Substation Indication LEDs"
From Zenitel Wiki
Line 1: | Line 1: | ||
[[Image:IP substation connections.jpg|280px|right|IP Substation Connections]] | [[Image:IP substation connections.jpg|280px|right|IP Substation Connections]] | ||
== Station LED (on board and in front plate) == | == Station LED (on board and in front plate) == | ||
− | Blinking 1 sec. interval | + | '''Blinking 1 sec. interval''': Station does not have connection to the AlphaCom E exchange. |
− | Possible reasons: | + | ''Possible reasons'': |
− | + | * No connection to Ethernet | |
− | + | * Wrong AlphaCom E IP address configured | |
− | + | * Invalid IP address | |
− | + | * No or wrong gateway to the AlphaCom E exchange | |
− | Blinking 5 sec. interval Station has connection to the AlphaCom E exchange, but has not | + | |
− | + | '''Blinking 5 sec. interval''': Station has connection to the AlphaCom E exchange, but has not been registered. | |
− | Reason: | + | ''Reason'': |
− | + | * Station has not been programmed in AlphaPro | |
− | No blinking | + | |
− | Possible reasons: | + | '''No blinking''' |
− | + | ''Possible reasons'': | |
− | + | * Station connected and registered to the AlphaCom E exchange - All OK | |
+ | * Station not powered up (if no other LEDs are active) | ||
== Status LED == | == Status LED == |
Revision as of 22:33, 10 October 2007
Station LED (on board and in front plate)
Blinking 1 sec. interval: Station does not have connection to the AlphaCom E exchange. Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom E IP address configured
- Invalid IP address
- No or wrong gateway to the AlphaCom E exchange
Blinking 5 sec. interval: Station has connection to the AlphaCom E exchange, but has not been registered. Reason:
- Station has not been programmed in AlphaPro
No blinking Possible reasons:
- Station connected and registered to the AlphaCom E exchange - All OK
- Station not powered up (if no other LEDs are active)
Status LED
Blinking 2 red + 1 green Station does not have connection to the AlphaCom E exchange Blinking 1 red + 2 green Station has connection to AlphaCom E exchange, but has not been registered Blinking 3 green Station connected and registered in the AlphaCom E exchange LAN LEDs (on LAN and AUX RJ45-jacks): Left green LED: - Steady light Ethernet connection OK - Blinking Ethernet traffic - No light No Ethernet connection Right amber LED: - Light 100 Mbit Ethernet connection - No light 10 Mbit Ethernet connection