Difference between revisions of "IP Substation Indication LEDs"
From Zenitel Wiki
Line 2: | Line 2: | ||
== Station LED (on board and in front plate) == | == Station LED (on board and in front plate) == | ||
'''Blinking 1 sec. interval''': Station does not have connection to the AlphaCom E exchange. | '''Blinking 1 sec. interval''': Station does not have connection to the AlphaCom E exchange. | ||
− | ''Possible reasons'': | + | :''Possible reasons'': |
− | * No connection to Ethernet | + | :* No connection to Ethernet |
− | * Wrong AlphaCom E IP address configured | + | :* Wrong AlphaCom E IP address configured |
− | * Invalid IP address | + | :* Invalid IP address |
− | * No or wrong gateway to the AlphaCom E exchange | + | :* No or wrong gateway to the AlphaCom E exchange |
'''Blinking 5 sec. interval''': Station has connection to the AlphaCom E exchange, but has not been registered. | '''Blinking 5 sec. interval''': Station has connection to the AlphaCom E exchange, but has not been registered. | ||
− | ''Reason'': | + | :''Reason'': |
− | * Station has not been programmed in AlphaPro | + | :* Station has not been programmed in AlphaPro |
− | '''No blinking''' | + | '''No blinking''' |
− | ''Possible reasons'': | + | :''Possible reasons'': |
− | * Station connected and registered to the AlphaCom E exchange - All OK | + | :* Station connected and registered to the AlphaCom E exchange - All OK |
− | * Station not powered up (if no other LEDs are active) | + | :* Station not powered up (if no other LEDs are active) |
== Status LED == | == Status LED == |
Revision as of 22:34, 10 October 2007
Station LED (on board and in front plate)
Blinking 1 sec. interval: Station does not have connection to the AlphaCom E exchange.
- Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom E IP address configured
- Invalid IP address
- No or wrong gateway to the AlphaCom E exchange
Blinking 5 sec. interval: Station has connection to the AlphaCom E exchange, but has not been registered.
- Reason:
- Station has not been programmed in AlphaPro
No blinking
- Possible reasons:
- Station connected and registered to the AlphaCom E exchange - All OK
- Station not powered up (if no other LEDs are active)
Status LED
Blinking 2 red + 1 green Station does not have connection to the AlphaCom E exchange Blinking 1 red + 2 green Station has connection to AlphaCom E exchange, but has not been registered Blinking 3 green Station connected and registered in the AlphaCom E exchange LAN LEDs (on LAN and AUX RJ45-jacks): Left green LED: - Steady light Ethernet connection OK - Blinking Ethernet traffic - No light No Ethernet connection Right amber LED: - Light 100 Mbit Ethernet connection - No light 10 Mbit Ethernet connection