Actions

IP Substation Indication LEDs

From Zenitel Wiki

Revision as of 22:34, 10 October 2007 by Asle (talk)
IP Substation Connections

Station LED (on board and in front plate)

Blinking 1 sec. interval: Station does not have connection to the AlphaCom E exchange.

Possible reasons:
  • No connection to Ethernet
  • Wrong AlphaCom E IP address configured
  • Invalid IP address
  • No or wrong gateway to the AlphaCom E exchange

Blinking 5 sec. interval: Station has connection to the AlphaCom E exchange, but has not been registered.

Reason:
  • Station has not been programmed in AlphaPro

No blinking

Possible reasons:
  • Station connected and registered to the AlphaCom E exchange - All OK
  • Station not powered up (if no other LEDs are active)

Status LED

Blinking 2 red + 1 green Station does not have connection to the AlphaCom E exchange Blinking 1 red + 2 green Station has connection to AlphaCom E exchange, but has not been registered Blinking 3 green Station connected and registered in the AlphaCom E exchange LAN LEDs (on LAN and AUX RJ45-jacks): Left green LED: - Steady light Ethernet connection OK - Blinking Ethernet traffic - No light No Ethernet connection Right amber LED: - Light 100 Mbit Ethernet connection - No light 10 Mbit Ethernet connection