Actions

IP Substation Indication LEDs

From Zenitel Wiki

Revision as of 22:45, 10 October 2007 by Asle (talk)
IP Substation Connections

Station LED (on board and in front plate)

Blinking at 1 second interval: Station does not have connection to the AlphaCom E exchange.

Possible reasons:
  • No connection to Ethernet
  • Wrong AlphaCom E IP address configured
  • Invalid IP address
  • No or wrong gateway to the AlphaCom E exchange

Blinking at 5 seconds interval: Station has connection to the AlphaCom E exchange, but has not been registered.

Reason:
  • Station has not been programmed in AlphaPro

No blinking

Possible reasons:
  • Station connected and registered to the AlphaCom E exchange - All OK
  • Station not powered up (if no other LEDs are active)

Status LED

  • Blinking 2 red + 1 green: Station does not have connection to the AlphaCom E exchange
  • Blinking 1 red + 2 green:Station has connection to AlphaCom E exchange, but has not been registered
  • Blinking 3 green: Station connected and registered in the AlphaCom E exchange

LAN LEDs (on LAN and AUX RJ45-jacks)

Left green LED:

  • Steady light: Ethernet connection OK
  • Blinking: Ethernet traffic
  • No light: No Ethernet connection

Right amber LED:

  • Light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection