Actions

Difference between revisions of "IP station as program"

From Zenitel Wiki

(Configuring IP station as Program Feed)
(Configuring IP station as Program Feed)
 
Line 1: Line 1:
 
==Configuring IP station as Program Feed==
 
==Configuring IP station as Program Feed==
From 11.3.3.1b it is possible to use an IP-ARIO as a program source.
+
From 11.3.3.1b it is possible to use an IP-ARIO as a program source. To achieve this an IP-ARIO with license registered to the exchange is required.
  
To achieve this an IP-ARIO with license registered to the exchange is required.
+
To setup an IP station as program feed the port type must be defined as '''"7 (AUDIO PROGRAM)"'''
  
In the example below the IP-ARIO is registered as physical number 20.
+
Board resource define the program to feed (1-38)
 
 
 
 
1) Set board use as "7 Audio Program Feed" (Exchange&System -> Board):
 
  
[[File:IPAudioProgram2.png|thumb|left|500px]]
+
In the example below the IP-ARIO is registered as physical number 20. It will be set as the program source to program 1 (Feature 5/1, Directory number 801)
<br style="clear:both;" />
+
* Create this event; (W20 equals the physical number of the IP-ARIO):
 
 
2) Create this event; (W20 equals the physical number of the IP-ARIO):
 
  
 
[[File:IPAudioProgram1.png|thumb|left|500px]]
 
[[File:IPAudioProgram1.png|thumb|left|500px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
3) Send changes and reset the exchange.
+
* Send changes and reset the exchange.
  
  
To setup an IP station as program feed the port type must be 7 (AUDIO PROGRAM)
+
Alternative nvram configuration from [[TST]]:
Board resource define the program to feed (1-38)
+
0 &501000 .module_profile.st_profile[20].port_profile.port_type = 7 (0x07)
 
+
3 &501003 .module_profile.st_profile[20].port_profile.board_resource = 1 (0x01)
0 &501000 .module_profile.st_profile[20].port_profile.port_type = 7 (0x07)
 
3 &501003 .module_profile.st_profile[20].port_profile.board_resource = 1 (0x01)
 

Latest revision as of 11:22, 2 July 2013

Configuring IP station as Program Feed

From 11.3.3.1b it is possible to use an IP-ARIO as a program source. To achieve this an IP-ARIO with license registered to the exchange is required.

To setup an IP station as program feed the port type must be defined as "7 (AUDIO PROGRAM)"

Board resource define the program to feed (1-38)

In the example below the IP-ARIO is registered as physical number 20. It will be set as the program source to program 1 (Feature 5/1, Directory number 801)

  • Create this event; (W20 equals the physical number of the IP-ARIO):
IPAudioProgram1.png


  • Send changes and reset the exchange.


Alternative nvram configuration from TST:
0 &501000 .module_profile.st_profile[20].port_profile.port_type = 7 (0x07)
3 &501003 .module_profile.st_profile[20].port_profile.board_resource = 1 (0x01)