Actions

Difference between revisions of "Light Industrial Master Station with Loudspeaker - 1007080000"

From Zenitel Wiki

(Installation)
Line 11: Line 11:
 
===<u>Dimensional Drawing</u>===
 
===<u>Dimensional Drawing</u>===
 
[[File:1007080000-dimensions 0.jpg|600px]]
 
[[File:1007080000-dimensions 0.jpg|600px]]
<br style="clear:both;" />
 
 
===<u>Installation</u>===
 
[[image:Light Industrial Master Station with Loudspeaker 100 7080 000 Installation.jpg|thumb|left|500px|]]
 
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  

Revision as of 10:53, 31 October 2016

Light Industrial Master Station

Highlights

  • Fully equipped splashproof master station with free access to all extensions and features
  • Flame- and chip-resistant plastic casing. Key board foil of UV-cured PVC. Resistant to corrosive fluids
  • Electret microphone and red microphone live lamp
  • Screw terminals for easy connection of installation cables
  • Built-in loudspeaker and possibility to connect an external speaker. Sound level adjustable with a potentiometer inside the station
  • Built-in 10W (8 Ohm) VOX operated power amplifier for external loudspeaker

Dimensional Drawing

1007080000-dimensions 0.jpg

Connections

Industrial Analogue Connections.png


Handset connection

When handset is connected, open shunt S8 and S11.

7080 handset conn.PNG


Handset troubleshooting

Symptom:

When an industrial station type 100 7080 000 is equipped with a handset there is a knows issue related to the handset operation: when the handset is replaced (on-hook) during conversation, the conversation does not cancel.

Solution:

A component must be changed on the station PCB; A100C01433, in order to make the converstion cancel. Change capacitor C14 (47µF/100V) to 4,7µF/63V.

7080 handset cancel.PNG


Additional Documentation on Zenitel.com