Syntax

MST  <[(node)]>  <destination phys. no>  <source phys. no>  <“mail-text”/mail-id> <[priority]>
  • Phys. no: 1-552
  • Mail text: Free text (maximum 16 characters) in quotes
  • Mail id: no 19-30 (see below)
  • Priority: 1-255

Mail id's:

Mail Number Mail Text Comment
1 Contact switchboard During conversation: 7+660
2 Call telephone During conversation: 7+661
6 Call home During conversation: 7+663
7 Call spouse During conversation: 7+664
10 Call me .. During conversation: 8 or 7+666
12 Remember meeting During conversation: 7+667
14 FAX for you During conversation: 7+668
15 Delivery for you During conversation: 7+669
17 Alarm Call Request Send Call Request Feature w/priority >= 120
18 Normal Call Request Send Call Request Feature
19 Technical Alarm 1  
20 Technical Alarm 2  
21 Technical Alarm 3  
22 Power Supply 3  
23 Power Supply 2  
24 Power Supply 1  
25 Standby Active  
26 Temperature Alarm  
27 Board error  
28 Line Error  
29 Device Error  
30 AGA Error  


Example

MST 47 0 “Temp. alarm”           – Send textmessage "Temp.alarm" to station 47
MST (3) 47 0 “Temp. alarm” 160   – Send "Temp.alarm" with priority 160 to station 47 in node 3
MST 1 0 28                       - Send line error (28) to station 1