'''46 FEAT_OUTPUT_TIME'''
+
{{AI}}
{| border="1"
+
{|  
!style="background:#ffdead;"|Param1
 
!style="background:#ffdead;"|Description
 
 
|-
 
|-
| ?? || Output "set clock" data message
+
|width="170pt"|'''Feature''':
 +
| Output "Set clock" MPC data message  
 
|-
 
|-
|colspan="2"|Control Room: Broadcast time.
+
|'''Default directory number''': || 7876
 +
|-
 +
|'''Feature number''': || 46
 +
|-valign="top"  
 +
|'''Parameter 1''': || 0 (N/A)
 +
|-valign="top"
 +
|'''Description''': || Some Control Room stations based on the [[MPC Data Protocol]] need time and date information. This feature broadcasts this information to all CRM stations.
  
Data message sent on MPC port.
+
Procedure:  Dial 7876.
|-
 
|}
 
  
 +
Data generated on the [[MPC Data Protocol]]:
 +
*0514 FFFF HHMM DDMM YYYY
  
 +
|}
 
[[AlphaCom Feature List|Back to feature list]]
 
[[AlphaCom Feature List|Back to feature list]]

Latest revision as of 09:46, 8 October 2019

AI.png
Feature: Output "Set clock" MPC data message
Default directory number: 7876
Feature number: 46
Parameter 1: 0 (N/A)
Description: Some Control Room stations based on the MPC Data Protocol need time and date information. This feature broadcasts this information to all CRM stations.

Procedure: Dial 7876.

Data generated on the MPC Data Protocol:

  • 0514 FFFF HHMM DDMM YYYY