Actions

Difference between revisions of "Play DAK Feature"

From Zenitel Wiki

(Timing of play speed)
(Play DAK by Data Protocol)
Line 33: Line 33:
  
 
===Play DAK by Data Protocol ===
 
===Play DAK by Data Protocol ===
If longer strings are needed the [[Station DAK key as RCI (Event Type)|Station DAK key as RCI]] event trigger can be used for sending the [[PLAY_DAK |PLAY_DAK ($PD)]] data protocol message.
+
If longer strings are needed the [[Station Input or Station DAK key (Event Type)|Station Input or Station DAK key]] event trigger can be used for sending the [[PLAY_DAK |PLAY_DAK ($PD)]] data protocol message.
  
 
===Restriction===
 
===Restriction===

Revision as of 14:00, 17 April 2019

AlphaCom icon 300px.png

Programming of DAK sequences with single digit dialing and wait states

Available from AMC 10.50

Play DAK programmed from DAK string

By using the DAK "T" parameter in the beginning of the DAK string, a 18 digit string can be programmed.

Sequence syntax:

0-9    Digits
# *    Signaling available during trunk connection
w      Pause for 0,5 Second 
W      Pause for 1 Second 

Example DAK string as programmed in AlphaPro:
AlphaPro Play DAK


Description:
Get line out "01"
Wait 1 Sec
Dial Tellog pin code "123#"
Wait 2 Sec
Dial Zenitel "40002500".

Timing of play speed

Default digit step time is 200 ms. Configurable from NVRAM:

.ex_profile.timeouts.play_dak_time = 2 (0x0002)


Play DAK by Data Protocol

If longer strings are needed the Station Input or Station DAK key event trigger can be used for sending the PLAY_DAK ($PD) data protocol message.

Restriction

Maximum 50 simultaneous DAK Play functions can be activated at the same time in one node.