Actions

Difference between revisions of "Program Direct Access Key feature"

From Zenitel Wiki

Line 23: Line 23:
 
|}
 
|}
  
784 programming is temporarily stored in the running configuration in RAM, and permanently synchronized to Flash after up to 4 hours. Flash is always synchronized after AlphaPro update (SendChg/SendAll) and before software reset if any pending changes. But there is no sync if sudden power or APC reset.
+
::'''Note:''' As from AMC 10.60.3.1 the 784 programming is temporarily stored in the running configuration in RAM, and permanently synchronized to Flash after up to 4 hours. Flash is always synchronized after AlphaPro update (SendChg/SendAll) and before software reset if any pending changes. But there is no sync if sudden power or APC reset.
 
   
 
   
So after 784 do a software reset from AlphaPro (or wait 4 hours...).
 
 
  
 
[[AlphaCom Feature List|Back to feature list]]
 
[[AlphaCom Feature List|Back to feature list]]

Revision as of 00:22, 7 March 2011

Feature: Program Direct Access Key
Default directory number: 784, 9541
Feature number: 32
Parameter 1:

0 = Standard program DAK
1 = Append mode
2 = Program diro during connection
4 = Extra digits only
8 = Program event trigger

0 (784)
128 (9541) (Same function as parameter 1 = 0)


Description: Program DAK key. Dial: <dir.no> <dak-sequence> <DAK-key>, e.g. 784 + 123 + DAK key.
Directory number 9541 is used in the menues of the Dual Display station
Note: As from AMC 10.60.3.1 the 784 programming is temporarily stored in the running configuration in RAM, and permanently synchronized to Flash after up to 4 hours. Flash is always synchronized after AlphaPro update (SendChg/SendAll) and before software reset if any pending changes. But there is no sync if sudden power or APC reset.


Back to feature list