Actions

Difference between revisions of "Recording Event (Event Type)"

From Zenitel Wiki

 
Line 20: Line 20:
  
 
Regarding the Event Owner:  
 
Regarding the Event Owner:  
 
+
* The owner of the event is the A-station in a conversation, or the initiator of a group call.
*The owner of the event is the A-station in a conversation, or the initiator of a group call.
+
* For Simplex conference, station "1" is always the owner. "Related To" is the conference directory number, e.g. "8201".
*For Simplex conference, station "1" is always the owner. "Related To" is the conference directory number, e.g. "8201".
 
  
 
==Additional information==
 
==Additional information==
 
+
* Sub-event 0:  ON = Recording "process" starts. OFF = Recording "process" stops. (This does not mean that the actual recording is taking place. For "recording on demand" the ON event will trigger when conversation starts, sub event 1 or 2 will trigger when or if $REC start the recording.)
*Sub-event 0:  ON = Recording "process" starts. OFF = Recording "process" stop. (This does not mean that the actual recording is taking place. For "recording on demand" the ON event will trigger when conversation starts, sub event 1 or 2 will trigger when or if $REC start the recording.)
+
* Sub-event 1:  ON = The Recorder "1" reply "OK" to recording audio session. (This means the "physical" recording starts)
*Sub-event 1:  ON = The Recorder "1" reply "OK" to recording audio session. (This means the "physical" recording starts)
+
* Sub-event 2:  ON = The Recorder "2" reply "OK" to recording audio session. (This means the "physical" recording starts)
*Sub-event 2:  ON = The Recorder "2" reply "OK" to recording audio session. (This means the "physical" recording starts)
+
* Sub-event 10: ON = No response from any of the recorders, this means the recording is failing at start up.
*Sub-event 10: ON = No response from any of the recorders, this means the recording is failing at start up.
+
* Sub-event 11: ON = Recorder terminated the recording session before the "audio" recording session was ended at the ICX-AlphaCom side.
*Sub-event 11: ON = Recorder terminated the recording session before the "audio" recording session was ended at AlphaCom side.
+
* Sub-event 20:  ON = SIP registration Recorder "1", OFF = SIP registration timeout. (ICX 1.0.3.3)
*Sub-event 20:  ON = SIP registration Recorder "1", OFF = SIP registration timeout. (ICX 1.0.3.3)
+
* Sub-event 21:  ON = SIP registration Recorder "2", OFF = SIP registration timeout (ICX 1.0.3.3)
*Sub-event 21:  ON = SIP registration Recorder "2", OFF = SIP registration timeout (ICX 1.0.3.3)
 
  
 
Available from alphasys 11.3.3.1.
 
Available from alphasys 11.3.3.1.
  
==Application==
 
  
[[Category:Event Handler]]
+
[[Category: Event Handler]]
[[Category:Event types]]
+
[[Category: Event types]]
[[Category:Recording]]
+
[[Category: Recording]]

Latest revision as of 12:07, 8 February 2024

AI.png


Event description

Event Owner: Station initiating the recording feature.
Event type: 40 - Recording Info
Subevent: Information type, see list below
When change to ON: When state is reported.
When change to OFF: Only for sub event 0 when recording ends.
When related to: Participant of the recording session. (B station, group call etc.)


Regarding the Event Owner:

  • The owner of the event is the A-station in a conversation, or the initiator of a group call.
  • For Simplex conference, station "1" is always the owner. "Related To" is the conference directory number, e.g. "8201".

Additional information

  • Sub-event 0: ON = Recording "process" starts. OFF = Recording "process" stops. (This does not mean that the actual recording is taking place. For "recording on demand" the ON event will trigger when conversation starts, sub event 1 or 2 will trigger when or if $REC start the recording.)
  • Sub-event 1: ON = The Recorder "1" reply "OK" to recording audio session. (This means the "physical" recording starts)
  • Sub-event 2: ON = The Recorder "2" reply "OK" to recording audio session. (This means the "physical" recording starts)
  • Sub-event 10: ON = No response from any of the recorders, this means the recording is failing at start up.
  • Sub-event 11: ON = Recorder terminated the recording session before the "audio" recording session was ended at the ICX-AlphaCom side.
  • Sub-event 20: ON = SIP registration Recorder "1", OFF = SIP registration timeout. (ICX 1.0.3.3)
  • Sub-event 21: ON = SIP registration Recorder "2", OFF = SIP registration timeout (ICX 1.0.3.3)

Available from alphasys 11.3.3.1.