== AlphaCom Configuration ==
+
== AlphaWeb Configuration ==
  
=== AlphaWeb Configuration ===
 
  
  
 
+
=== Insert SIP Trunk licenses ===
==== Insert SIP Trunk licenses ====
 
 
Log on to AlphaWeb and install the '''SIP Stations''' license.
 
Log on to AlphaWeb and install the '''SIP Stations''' license.
  
Line 18: Line 16:
 
<br>
 
<br>
  
==== Firewall (filter) settings ====
+
=== Firewall (filter) settings ===
 
Enable the SIP protocol on the desired Ethernet port (default enabled for Ethernet port1).
 
Enable the SIP protocol on the desired Ethernet port (default enabled for Ethernet port1).
  
Line 29: Line 27:
 
<br>
 
<br>
  
=== AlphaPro Configuration ===
+
== AlphaPro Configuration ==
==== Create a SIP Registrar Node ====
+
=== Create a SIP Registrar Node ===
 
From the AlphaPro main menu, use the ‘+’ button next to the ‘Select Exchange’ dropdown list to create a new exchange. The exchange type must be set to ‘SIP Node’.
 
From the AlphaPro main menu, use the ‘+’ button next to the ‘Select Exchange’ dropdown list to create a new exchange. The exchange type must be set to ‘SIP Node’.
  
Line 41: Line 39:
 
'''Note:''' If the AlphaCom is configured with a SIP Trunk node in addition to the SIP Registrar node, the SIP Registar node must have a lower node number than the SIP Trunk node.
 
'''Note:''' If the AlphaCom is configured with a SIP Trunk node in addition to the SIP Registrar node, the SIP Registar node must have a lower node number than the SIP Trunk node.
  
==== Define the AlphaCom <-> SIP routing ====
+
=== Define the AlphaCom <-> SIP routing ===
 
In '''Exchange & System > Net Routing''' use the ''Insert'' button to create a route between the AlphaCom and SIP Registrar node. Choose '''Data: ACDP Link''' = ''SIP Link'', and set '''Preferred codec''' to ''G711u'' and '''RTP Packet Size''' to ''10 ms''.
 
In '''Exchange & System > Net Routing''' use the ''Insert'' button to create a route between the AlphaCom and SIP Registrar node. Choose '''Data: ACDP Link''' = ''SIP Link'', and set '''Preferred codec''' to ''G711u'' and '''RTP Packet Size''' to ''10 ms''.
  
 
[[image:Configuration guide for AudioCodes MP114 118 - Define the AlphaCom SIP routing.jpg]]
 
[[image:Configuration guide for AudioCodes MP114 118 - Define the AlphaCom SIP routing.jpg]]
  
==== Create SIP phone number ====
+
=== Create SIP phone number ===
 
The directory number of the SIP phone(s) must be programmed in the AlphaCom directory table (Directory & Features menu) with ''feature'' 83 and '''Node''' = SIP Registrar node number (100 in this example). In the example below a SIP phone has been assigned directory number 9555.
 
The directory number of the SIP phone(s) must be programmed in the AlphaCom directory table (Directory & Features menu) with ''feature'' 83 and '''Node''' = SIP Registrar node number (100 in this example). In the example below a SIP phone has been assigned directory number 9555.
 
[[Image:AlphaPro Add SIP Phone.jpg]]
 
[[Image:AlphaPro Add SIP Phone.jpg]]
  
==== Update the exchange ====
+
=== Update the exchange ===
 
Log on to the exchange and update the exchange by pressing the
 
Log on to the exchange and update the exchange by pressing the
 
SendAll button.
 
SendAll button.
  
 
[[Category:SIP]]
 
[[Category:SIP]]

Revision as of 16:34, 4 December 2007

AlphaWeb Configuration

Insert SIP Trunk licenses

Log on to AlphaWeb and install the SIP Stations license.

Configuration guide for AudioCodes MP114 118 - Insert SIP Trunk licenses.jpg









Firewall (filter) settings

Enable the SIP protocol on the desired Ethernet port (default enabled for Ethernet port1).

Configuration guide for AudioCodes MP114 118 - Firewall (filter) settings.jpg







AlphaPro Configuration

Create a SIP Registrar Node

From the AlphaPro main menu, use the ‘+’ button next to the ‘Select Exchange’ dropdown list to create a new exchange. The exchange type must be set to ‘SIP Node’.

AlphaPro Create SIP Registrar.jpg


  • Select the AlphaCom node number which the SIP Registrar should be related to (normally node 1)
  • Choose which of the ethenet ports 0 or 1 the SIP phones should use

Note: If the AlphaCom is configured with a SIP Trunk node in addition to the SIP Registrar node, the SIP Registar node must have a lower node number than the SIP Trunk node.

Define the AlphaCom <-> SIP routing

In Exchange & System > Net Routing use the Insert button to create a route between the AlphaCom and SIP Registrar node. Choose Data: ACDP Link = SIP Link, and set Preferred codec to G711u and RTP Packet Size to 10 ms.

Configuration guide for AudioCodes MP114 118 - Define the AlphaCom SIP routing.jpg

Create SIP phone number

The directory number of the SIP phone(s) must be programmed in the AlphaCom directory table (Directory & Features menu) with feature 83 and Node = SIP Registrar node number (100 in this example). In the example below a SIP phone has been assigned directory number 9555. AlphaPro Add SIP Phone.jpg

Update the exchange

Log on to the exchange and update the exchange by pressing the SendAll button.