Difference between revisions of "SIP registrar node - configuration"
From Zenitel Wiki
(→Define the AlphaCom <-> SIP routing) |
|||
Line 1: | Line 1: | ||
− | == | + | == AlphaWeb Configuration == |
− | |||
− | + | === Insert SIP Trunk licenses === | |
− | |||
Log on to AlphaWeb and install the '''SIP Stations''' license. | Log on to AlphaWeb and install the '''SIP Stations''' license. | ||
Line 18: | Line 16: | ||
<br> | <br> | ||
− | + | === Firewall (filter) settings === | |
Enable the SIP protocol on the desired Ethernet port (default enabled for Ethernet port1). | Enable the SIP protocol on the desired Ethernet port (default enabled for Ethernet port1). | ||
Line 29: | Line 27: | ||
<br> | <br> | ||
− | + | == AlphaPro Configuration == | |
− | + | === Create a SIP Registrar Node === | |
From the AlphaPro main menu, use the ‘+’ button next to the ‘Select Exchange’ dropdown list to create a new exchange. The exchange type must be set to ‘SIP Node’. | From the AlphaPro main menu, use the ‘+’ button next to the ‘Select Exchange’ dropdown list to create a new exchange. The exchange type must be set to ‘SIP Node’. | ||
Line 41: | Line 39: | ||
'''Note:''' If the AlphaCom is configured with a SIP Trunk node in addition to the SIP Registrar node, the SIP Registar node must have a lower node number than the SIP Trunk node. | '''Note:''' If the AlphaCom is configured with a SIP Trunk node in addition to the SIP Registrar node, the SIP Registar node must have a lower node number than the SIP Trunk node. | ||
− | + | === Define the AlphaCom <-> SIP routing === | |
In '''Exchange & System > Net Routing''' use the ''Insert'' button to create a route between the AlphaCom and SIP Registrar node. Choose '''Data: ACDP Link''' = ''SIP Link'', and set '''Preferred codec''' to ''G711u'' and '''RTP Packet Size''' to ''10 ms''. | In '''Exchange & System > Net Routing''' use the ''Insert'' button to create a route between the AlphaCom and SIP Registrar node. Choose '''Data: ACDP Link''' = ''SIP Link'', and set '''Preferred codec''' to ''G711u'' and '''RTP Packet Size''' to ''10 ms''. | ||
[[image:Configuration guide for AudioCodes MP114 118 - Define the AlphaCom SIP routing.jpg]] | [[image:Configuration guide for AudioCodes MP114 118 - Define the AlphaCom SIP routing.jpg]] | ||
− | + | === Create SIP phone number === | |
The directory number of the SIP phone(s) must be programmed in the AlphaCom directory table (Directory & Features menu) with ''feature'' 83 and '''Node''' = SIP Registrar node number (100 in this example). In the example below a SIP phone has been assigned directory number 9555. | The directory number of the SIP phone(s) must be programmed in the AlphaCom directory table (Directory & Features menu) with ''feature'' 83 and '''Node''' = SIP Registrar node number (100 in this example). In the example below a SIP phone has been assigned directory number 9555. | ||
[[Image:AlphaPro Add SIP Phone.jpg]] | [[Image:AlphaPro Add SIP Phone.jpg]] | ||
− | + | === Update the exchange === | |
Log on to the exchange and update the exchange by pressing the | Log on to the exchange and update the exchange by pressing the | ||
SendAll button. | SendAll button. | ||
[[Category:SIP]] | [[Category:SIP]] |
Revision as of 16:34, 4 December 2007
Contents
AlphaWeb Configuration
Insert SIP Trunk licenses
Log on to AlphaWeb and install the SIP Stations license.
Firewall (filter) settings
Enable the SIP protocol on the desired Ethernet port (default enabled for Ethernet port1).
AlphaPro Configuration
Create a SIP Registrar Node
From the AlphaPro main menu, use the ‘+’ button next to the ‘Select Exchange’ dropdown list to create a new exchange. The exchange type must be set to ‘SIP Node’.
- Select the AlphaCom node number which the SIP Registrar should be related to (normally node 1)
- Choose which of the ethenet ports 0 or 1 the SIP phones should use
Note: If the AlphaCom is configured with a SIP Trunk node in addition to the SIP Registrar node, the SIP Registar node must have a lower node number than the SIP Trunk node.
Define the AlphaCom <-> SIP routing
In Exchange & System > Net Routing use the Insert button to create a route between the AlphaCom and SIP Registrar node. Choose Data: ACDP Link = SIP Link, and set Preferred codec to G711u and RTP Packet Size to 10 ms.
Create SIP phone number
The directory number of the SIP phone(s) must be programmed in the AlphaCom directory table (Directory & Features menu) with feature 83 and Node = SIP Registrar node number (100 in this example). In the example below a SIP phone has been assigned directory number 9555.
Update the exchange
Log on to the exchange and update the exchange by pressing the SendAll button.