Actions

ST STATE

From Zenitel Wiki

Revision as of 08:52, 8 May 2013 by Aksel (talk)
ST_STATE 0x009A 154 AMC 10.23
Response to the GET_ST_STATE message.
Current status of a station <br\> Illegal station or no more stations available will return ST_STATE without parameters
1 UINT2 1 -> 552: Station Physical Number
2 NET_OBJ_REF<br\>{ECL_STATION} Default user Directory Number
3 TEXT16 Default user Display text
4 UINT4 State bitmap Bits:<br\>

1: 0 = Free, 1 = Busy <br\> 2: 0 = A station, 1 = B station in communication.(Param 8. describe related station) <br\> 3: 0 = M-rel, 1 = M-pres <br\> 4: 0 = Hook on, 1 = Hook off <br\> (*)5: 0 = privat off, 1 = private on <br\> 6: 0 = No mail, 1 = Mail in queue <br\> 7: 0 = Tone test OK, 1 = Failed. (11.1.3.2)
25-32 = UDP groups as bitmap.

5 UINT1 Line State <br\>

0 Board not present <br\> 1 SLI board present, no station <br\> 2 SLI board present, station with failure <br\> 3 Station connected to SLI board <br\> 16 IP station configured, not connected <br\> 17 IP station connected but not authorized <br\> 18 IP station connected and registered OK, auth not required <br\> 19 IP station connected and authorized <br\> 20 IP station connected but no license available <br\>

6 UINT2 (*)Station RCI bitmap <br\>

1: RCI 1, 0 = off, 1 = on <br\> 2: RCI 2....<br\>

7 UINT2 (*)Station RCO bitmap <br\>

1: RCO 1, 0 = off, 1 = on <br\> 2: RCO 2....<br\>

8 NET_OBJ_REF (Empty REF in no conn active)Related station in connection.
9 UINT2 (0 if no conn active)Connection reference as given in CONN_STATUS_BC
10 UINT1 (0 if no conn active)CALL status as given in CALL_STATUS_BC
11 UINT4 IP station hardware type.

IP HW type ID :
32800 0x8020 IP Dual Display <br\> 32801 0x8021 SUB station board 1 <br\> 32802 0x8022 SUB station board 2 <br\> 32803 0x8023 Console board <br\> 32804 0x8024 IP Desktop <br\> 28708 0x7024 SoftClient <br\> 32806 0x8026 IP-ARIO <br\> 33568 0x8320 PA 1 <br\> 33584 0x8330 PA 2 <br\> 00256 0x0100 SIP Phone <br\> 00257 0x0101 IP Dummy station <br\> 00000 0x0000 Analog station/no station <br\>

12 UINT1 Station type as defined in AlphaPro <br\>

Station type codes:
0 Master Station <br\> 1 Sub Station <br\> 2 PNCI <br\> 3 CRM station <br\> 4 InterGuard <br\> 5 DualDisplay <br\> 6 Custom <br\> 7 SIP station <br\> 8 Conference Mixer <br\>

13 UINT4 IPARIO status flags

Bit number:
0 Amplifier 1, fault relay
1 Amplifier 2, fault relay
2 Amplifier 1, 24VDC fault
3 Amplifier 2, 24VDC fault
4 Amplifier 1, Speaker Loop Monitoring 1
5 Amplifier 2, Speaker Loop Monitoring 2
6 Amplifier 1, XLR Connected
7 Amplifier 2, XLR Connected

10 IPARIO down
11 $PA_CMD "ACK"
12 --$PA_CMD "CLEAR"
13 Fault led steady. (Fault acknowledged)
14 Fault led blinking. (Fault not acknowledged)


Response to: GET_ST_STATE
(*) Not implemented yet


ST_STATE will be reported to the OPC server when:

  • Mail queue changes from 0 to 1 or 1 to 0.
  • Line state changes(Line fault etc)
  • RCI changes on IP station.
  • RCO changes on IP station.

Note: This command require an OPC Server license

Back to AlphaNet message list