Actions

Serial port pinout

From Zenitel Wiki

Revision as of 11:03, 16 May 2013 by Asle (talk) (AlphaCom - RIO cabling)

The AlphaCom E exchanges has two serial ports. In AlphaCom E20 and E26 they are available on RJ45 connectors. In AlphaCom E7 the serial port 0 is on a 9 pin DSUB connector, and the serial port 1 is on a RJ45 connector.

The serial port 0 is RS232 only, the serial port 1 can be RS232, RS422 or RS485.

Pinout of the RJ45 connector:

RJ45 pinout


RJ45 pinout
RS232 3 = TX<br\>6 = RX<br\> 4&5 = GND
RS422 1 = RX-<br\>2 = RX+<br\>7 = TX-<br\>8 = TX+
RS485 1/7 = Data - <br\> 2/8 = Data+

<br\><br\>

Adaptor cable from RJ-45 to 9-pin Female D-SUB:

RJ45 - AlphaCom E 9 p Female DSUB
3 2
4&5 5
6 3



AlphaCom - RIO cabling

Cabling between the RIO unit and AlphaCom E using multidrop RS485:

 AlphaCom               RIO #1                  RIO #n           
 Serial 1             15 pin DSUB             15 pin DSUB
  RJ45

   1 -----------------+-- 2 --+----------------+-- 2
                      |       |                |
                      --- 4 ---                --- 4

   2 -----------------+-- 9 --+----------------+-- 9
                      |       |                |
                      --- 11---                --- 11

In the 15 pin DSUB of the RIO unit pin 2 & 4 and 9 & 11 must be connected together.

Cabling between the RIO unit and AlphaCom XE using point to point RS232:

 AlphaCom                   RIO                             
 Serial 1               9 pin DSUB             
  RJ45

   3 (TX) ---------------+-- 2 --+
                                                          
   6 (RX) ---------------+-- 3 --+
  
   5 (GND) --------------+-- 5 --+