Actions

Difference between revisions of "Status LED"

From Zenitel Wiki

Line 1: Line 1:
 
{{stub}}
 
{{stub}}
The [[status LED]] is located in front of the cabinet ([[AlphaCom E20]] and [[AlphaCom E26]]). The status LED indicate the following statuses:
+
The [[status LED]] indicator is located in front of the cabinet ([[AlphaCom E20]] and [[AlphaCom E26]]). The status LED is steady green when all is in order. Error indications:
* System startup (Red -> Amber -> Green light)
+
* System startup: Red -> Amber -> Green light
* Board error (Red light)
+
* Board error: Red light
* [[RCI|Remote Control Input]] (RCI) active. Requires software configuration from [[AlphaPro]].
+
* MultiModule:
 +
**Master module: Red light if the master module has lost contact with the slave(s)
 +
**Slave odule(s): If a slave has lost contact with the Master, the LED will light steady amber while the slave is rebooting, then the LED shows green when the module has come up in autonomy mode
 +
* [[RCI|Remote Control Input]] (RCI): Red light when RCI is active. Requires software configuration from [[AlphaPro]].
  
  
 
The status LED can be reset by the [[Reset_Board_Error_Indication_feature|7871 code]].
 
The status LED can be reset by the [[Reset_Board_Error_Indication_feature|7871 code]].

Revision as of 13:18, 3 January 2008

The status LED indicator is located in front of the cabinet (AlphaCom E20 and AlphaCom E26). The status LED is steady green when all is in order. Error indications:

  • System startup: Red -> Amber -> Green light
  • Board error: Red light
  • MultiModule:
    • Master module: Red light if the master module has lost contact with the slave(s)
    • Slave odule(s): If a slave has lost contact with the Master, the LED will light steady amber while the slave is rebooting, then the LED shows green when the module has come up in autonomy mode
  • Remote Control Input (RCI): Red light when RCI is active. Requires software configuration from AlphaPro.


The status LED can be reset by the 7871 code.