Actions

TFIX Connections

From Zenitel Wiki

Revision as of 18:04, 2 January 2017 by Asle (talk)
TFIX connections

All connections are made on the main board inside the enclosure of the Turbine Ex station.

Audio connections

The blue connector is marked +, -, S, and numbers 1 to 9. These should be utilized as follows:

J13 + Integrated Mic +
- Integrated Mic -
S Chassis ground
J6 1 Audio accessory speaker +
2 Audio accessory speaker -
3 Audio accessory microphone mic +
J7 4 Audio accessory microphone mic -
5 Audio accessory Push To Talk (PTT)
6 Audio accessory Hook
J9 7 Audio accessory Ground PTT/Hook
8 Loudspeaker +
9 Loudspeaker -



Flowire connection

Procedures for connecting power supply, LAN network and Inputs/Outputs are described in the manual A100K11499 Ex Turbine Intercoms & Exigo Access Panels Installation & Maintenance Procedures.