− | [[File:TFIXV2 Speaker | + | [[File:TFIXV2 Speaker Single2.png|thumb|left|500px]][[File:TFIXv2Speaker.png|thumb|left|500px|Detailed connection diagram]]{{Obs|The second power supply must have 1 volt lower value measured at the TFIX-V2 input. This adjustment must be performed during commissioning, while both the Flowire link and the secondary power supply is connected and running. }} |
+ | |||
==TFIX V2 with beacon== | ==TFIX V2 with beacon== | ||
A single TFIX V2 with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field. | A single TFIX V2 with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field. |
Revision as of 14:54, 14 March 2022
In noisy areas an external speaker and/or a beacon lamp can be used to indicate an incoming call or PA announcement.
TFIX V2 with external speaker and beacon
A single TFIX V2 with external speaker and beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:
- 1 Flowire unit; FCDC3 (item 1008080310)
- 1 48VDC Flowire PSU (item 2990000065)
- 1 48VDC PSU for external speaker and beacon (item 2990000065)
A junction box is needed out in the field to split the 48VDC between the TFIX V2 second power input and the beacon.
- 1 Junction Box (item 2340110016)
TFIX V2 with external speaker
A single TFIX V2 with external speaker in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:
- 1 Flowire unit; FCDC3 (item 1008080310)
- 1 48VDC Flowire PSU (item 2990000065)
- 1 48VDC PSU for external speaker (item 2990000065)
TFIX V2 with beacon
A single TFIX V2 with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:
- 1 Flowire unit; FCDC3 (item 1008080310)
- 1 48VDC Flowire PSU (item 2990000065)