Difference between revisions of "TFIX V2 - Installation Solutions"
From Zenitel Wiki
(Blanked the page) (Tag: Blanking) |
ZenitelAus (talk | contribs) (Tag: Visual edit) |
||
(13 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{AI}}In noisy areas an external speaker and/or a beacon lamp can be used to indicate an incoming call or PA announcement. | ||
+ | == Options == | ||
+ | |||
+ | ===TFIX V2 with external speaker and beacon=== | ||
+ | A single TFIX V2 with external speaker and beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field. | ||
+ | |||
+ | The cabinet consist of: | ||
+ | |||
+ | *1 Flowire unit; FCDC3 (item 1008080310) | ||
+ | *1 48VDC Flowire PSU (item 2990000065) | ||
+ | *1 48VDC PSU for beacon (item 2990000065) | ||
+ | |||
+ | [[File:TFIXV2 Speaker Beacon Single.png|thumb|left|500px]] | ||
+ | [[File:TFIXv2SpeakerBeacon.png|thumb|left|500px|Detailed connection diagram]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | ===TFIX V2 with external speaker=== | ||
+ | A single TFIX V2 with external speaker in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field. | ||
+ | |||
+ | The cabinet consist of: | ||
+ | |||
+ | *1 Flowire unit; FCDC3 (item 1008080310) | ||
+ | *1 48VDC Flowire PSU (item 2990000065) | ||
+ | |||
+ | [[File:TFIXV2 Speaker Single2.png|thumb|left|500px]] | ||
+ | [[File:TFIXv2Speaker.png|thumb|left|500px|Detailed connection diagram]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | ===TFIX V2 with beacon=== | ||
+ | A single TFIX V2 with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field. | ||
+ | |||
+ | The cabinet consist of: | ||
+ | |||
+ | *1 Flowire unit; FCDC3 (item 1008080310) | ||
+ | *1 48VDC Flowire PSU (item 2990000065) | ||
+ | |||
+ | [[File:TFIXV2 Beacon Single.png|thumb|left|500px]] | ||
+ | [[File:TFIXv2Beacon.png|thumb|left|500px|Detailed connection diagram]] | ||
+ | <br style="clear:both;" /> |
Latest revision as of 03:12, 3 July 2023
In noisy areas an external speaker and/or a beacon lamp can be used to indicate an incoming call or PA announcement.
Contents
Options
TFIX V2 with external speaker and beacon
A single TFIX V2 with external speaker and beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:
- 1 Flowire unit; FCDC3 (item 1008080310)
- 1 48VDC Flowire PSU (item 2990000065)
- 1 48VDC PSU for beacon (item 2990000065)
TFIX V2 with external speaker
A single TFIX V2 with external speaker in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:
- 1 Flowire unit; FCDC3 (item 1008080310)
- 1 48VDC Flowire PSU (item 2990000065)
TFIX V2 with beacon
A single TFIX V2 with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:
- 1 Flowire unit; FCDC3 (item 1008080310)
- 1 48VDC Flowire PSU (item 2990000065)