{{AI}}In noisy areas an external speaker and/or a beacon lamp can be used to indicate an incoming call or PA announcement.
 
{{AI}}In noisy areas an external speaker and/or a beacon lamp can be used to indicate an incoming call or PA announcement.
==TFIX V2 with external speaker and beacon==
+
===TFIX V2 with external speaker and beacon===
 
A single TFIX V2 with external speaker and beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.  
 
A single TFIX V2 with external speaker and beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.  
  
Line 13: Line 13:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
==TFIX V2 with external speaker==
+
===TFIX V2 with external speaker===
 
A single TFIX V2 with external speaker in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.  
 
A single TFIX V2 with external speaker in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.  
  
Line 25: Line 25:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
==TFIX V2 with beacon==
+
===TFIX V2 with beacon===
 
A single TFIX V2 with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.  
 
A single TFIX V2 with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.  
  

Revision as of 03:09, 3 July 2023

AI.png

In noisy areas an external speaker and/or a beacon lamp can be used to indicate an incoming call or PA announcement.

TFIX V2 with external speaker and beacon

A single TFIX V2 with external speaker and beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.

The cabinet consist of:

  • 1 Flowire unit; FCDC3 (item 1008080310)
  • 1 48VDC Flowire PSU (item 2990000065)
  • 1 48VDC PSU for beacon (item 2990000065)
TFIXV2 Speaker Beacon Single.png
Detailed connection diagram


TFIX V2 with external speaker

A single TFIX V2 with external speaker in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.

The cabinet consist of:

  • 1 Flowire unit; FCDC3 (item 1008080310)
  • 1 48VDC Flowire PSU (item 2990000065)
TFIXV2 Speaker Single2.png
Detailed connection diagram


TFIX V2 with beacon

A single TFIX V2 with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.

The cabinet consist of:

  • 1 Flowire unit; FCDC3 (item 1008080310)
  • 1 48VDC Flowire PSU (item 2990000065)
TFIXV2 Beacon Single.png
Detailed connection diagram