Actions

Difference between revisions of "VSF-Fortitude6 6.2 Release Notes"

From Zenitel Wiki

(Issues fixed)
 
(7 intermediate revisions by one other user not shown)
Line 1: Line 1:
==Release info==
+
Previous Release - [[VSF-Fortitude6 6.1 Release Notes]]
 +
 
 +
Next Release - [[VSF-Fortitude6 6.4 Release Notes]]
 +
 
 
This document provides the release notes for VSF-Fortitude6 6.2 with incremental bug fix releases. The release notes for VSF-Fortitude6 6.2 describe new features, improvements and issues fixed after VSF-Fortitude6 6.1.
 
This document provides the release notes for VSF-Fortitude6 6.2 with incremental bug fix releases. The release notes for VSF-Fortitude6 6.2 describe new features, improvements and issues fixed after VSF-Fortitude6 6.1.
  
 +
==Release info==
 
'''Name:''' VSF-Fortitude6 <br>
 
'''Name:''' VSF-Fortitude6 <br>
 
'''Description:''' VSF-Fortitude6 is a firmware for [[IP Desk Master -V2]], [[IP Flush Master -V2]] and [[IP-CROR]].
 
'''Description:''' VSF-Fortitude6 is a firmware for [[IP Desk Master -V2]], [[IP Flush Master -V2]] and [[IP-CROR]].
Line 10: Line 14:
 
*vsff6-prod-6.2.3.x - Used in production- and recovery upgrades.
 
*vsff6-prod-6.2.3.x - Used in production- and recovery upgrades.
  
'''Version:''' 6.2.3.0<br>
+
'''Version:''' 6.2.3.1<br>
'''Date:''' 30.06.2021 <br>
+
'''Date:''' 09.08.2021 <br>
 
'''Status:''' General Availability<br>
 
'''Status:''' General Availability<br>
 
'''Compatibility: ''' IP Desk Master V2 and IP Flush Master V2 and  IP-CROR are compatible with Edge, SIP, ICX and AlphaCom systems.
 
'''Compatibility: ''' IP Desk Master V2 and IP Flush Master V2 and  IP-CROR are compatible with Edge, SIP, ICX and AlphaCom systems.
 +
 +
<br>
 +
 +
=VSF-FORTITUDE6 6.2.3.1=
 +
==Issues fixed==
 +
===MTN-3403 IP Flush Master V2 and IP-CROR in ICX-AlphaCom mode needed 3 button press to change LCD brightness===
 +
IP Flush Master V2 and CROR in ICX-AlphaCom mode needed 3 button press to change LCD brightness, it now needs only one press.
 +
 +
===MTN-3400 LCD backlight steps on IP Flush Master V2 and IP CROR===
 +
LCD backlight steps have been changed for IP Flush Master V2 and IP-CROR, minimum brightness is now lower than before
 +
 +
===MTN-3384 Keypad dimming has been fixed for IP Flush Master V2.===
 +
 +
===MTN-3377 Fixed behaviour of IP Desk Master V2 while Audio program is active===
 +
When handset of IP Desk Master V2 was offhook when alarm started to play, and handset is put back in cradle, dial tone would start playing on loudspeaker. This is now fixed, so alarm is played on loudspeaker.
 +
Further, when handset was onhook when alarm started, and then raised, dial tone would start to play on loudspeaker. This is now fixed, so both alarm and dial tone/conversation can be heard in the handset.
 +
 +
===MTN-3255 Calls going through 3CX SBC hangs up after 30 seconds===
 +
The record-route handling for strict routing did not work properly. This is now fixed.
  
 
<br>
 
<br>
  
 
=VSF-FORTITUDE6 6.2.3.0=
 
=VSF-FORTITUDE6 6.2.3.0=
==Improvements ==
+
==Improvements==
=== MTN-3258 Removed support for TLSv1.0===  
+
===RED-46 IPv6 is supported in SIP mode===  
Support for TLSv1.0 is now removed, only TLSv1.1 or newer is supported.
 
  
=== MTN-3164 Option to adjust microphone sensitivity for accessories===  
+
===MTN-3350 ICX-AlphaCom server's IP is now shown in device info menu when device is not connected===  
Option is now available to adjust microphone sensitivity for accessories of IP Flush Master-V2 and IP-CROR
+
If IP address of the ICX-AlphaCom server was configured, but not connected to ICX-AlphaCom server, IP address 0.0.0.0 would show in device info on the device itself. This is now fixed. The IP of the ICX-AlphaCom server is displayed on the device even if it has lost connection to the ICX-AlphaCom server.
  
=== MTN-3093 Improved Tone test to combat noisy environment and to be able to use in places with multiple stations in the close vicinity ===
+
<br>
Tone volume is automatically adjusted to suit the ambient noise levels and therefore make it suitable to use it in noisy environment. Further improvement is made for environments like a train where multiple stations are next to each other. This might have caused the intercom with faulty speaker picks up tone from another station doing the test at the same time and wrongly reports success. This is now solved by playing multiple frequency tones.
 
  
<br>
+
==Issues fixed==
 +
===MTN-3180 IP flush master now only shows 1 relay in configuration===
 +
Before there was incorrect option to select up to 3 relays but it is only 1 relay that is actually existing on device.
 +
 
 +
===MTN-3334 TLS 1.1. support over https is removed from devices=== 
  
== Issues fixed ==
+
===MTN-3343 Set time manually has been fixed for IP Desk Master V2 devices in Edge and SIP mode===  
=== MTN-3260 Syslog settings sometimes required reboot to take effect.===  
 
Sometimes syslog settings required reboot to take effect. This is now fixed and reboot is no longer required.
 
  
=== MTN-3244 Station fails to register to CUCM when using default registration intervals.===  
+
===MTN-3352 Issue with headset on IP Desk Master-V2 is now fixed===  
Station could not register to Cisco Unified Call Manager (CUCM) when default registration intervals were used. This is now fixed.
+
If headset on the IP Desk Master-V2 was used, the headset would not be detected after use of the handset. This is now fixed.
  
=== MTN-3234 IP Flush Master DAK 1 led issue resolved.===  
+
===MTN-3355 The three inputs on the PCB of the IP Desk Master-V2 are now supported===  
IP Flush Master had invalid led handling on DAK 1 outside of call.
 
  
=== MTN-3136 Backlight is off when IP Desk Master V2 is set to CRM===
 
The backlight should automatically turn on, when it is set to CRM. This is now working.
 
  
 
<br>
 
<br>
 
  
 
[[Category: Release notes]]
 
[[Category: Release notes]]

Latest revision as of 05:02, 8 March 2022

Previous Release - VSF-Fortitude6 6.1 Release Notes

Next Release - VSF-Fortitude6 6.4 Release Notes

This document provides the release notes for VSF-Fortitude6 6.2 with incremental bug fix releases. The release notes for VSF-Fortitude6 6.2 describe new features, improvements and issues fixed after VSF-Fortitude6 6.1.

Release info

Name: VSF-Fortitude6
Description: VSF-Fortitude6 is a firmware for IP Desk Master -V2, IP Flush Master -V2 and IP-CROR.

The firmware is delivered in two different files:

  • vsff6-6.2.3.x - Used for standard in-field upgrades
  • vsff6-prod-6.2.3.x - Used in production- and recovery upgrades.

Version: 6.2.3.1
Date: 09.08.2021
Status: General Availability
Compatibility: IP Desk Master V2 and IP Flush Master V2 and IP-CROR are compatible with Edge, SIP, ICX and AlphaCom systems.


VSF-FORTITUDE6 6.2.3.1

Issues fixed

MTN-3403 IP Flush Master V2 and IP-CROR in ICX-AlphaCom mode needed 3 button press to change LCD brightness

IP Flush Master V2 and CROR in ICX-AlphaCom mode needed 3 button press to change LCD brightness, it now needs only one press.

MTN-3400 LCD backlight steps on IP Flush Master V2 and IP CROR

LCD backlight steps have been changed for IP Flush Master V2 and IP-CROR, minimum brightness is now lower than before

MTN-3384 Keypad dimming has been fixed for IP Flush Master V2.

MTN-3377 Fixed behaviour of IP Desk Master V2 while Audio program is active

When handset of IP Desk Master V2 was offhook when alarm started to play, and handset is put back in cradle, dial tone would start playing on loudspeaker. This is now fixed, so alarm is played on loudspeaker. Further, when handset was onhook when alarm started, and then raised, dial tone would start to play on loudspeaker. This is now fixed, so both alarm and dial tone/conversation can be heard in the handset.

MTN-3255 Calls going through 3CX SBC hangs up after 30 seconds

The record-route handling for strict routing did not work properly. This is now fixed.


VSF-FORTITUDE6 6.2.3.0

Improvements

RED-46 IPv6 is supported in SIP mode

MTN-3350 ICX-AlphaCom server's IP is now shown in device info menu when device is not connected

If IP address of the ICX-AlphaCom server was configured, but not connected to ICX-AlphaCom server, IP address 0.0.0.0 would show in device info on the device itself. This is now fixed. The IP of the ICX-AlphaCom server is displayed on the device even if it has lost connection to the ICX-AlphaCom server.


Issues fixed

MTN-3180 IP flush master now only shows 1 relay in configuration

Before there was incorrect option to select up to 3 relays but it is only 1 relay that is actually existing on device.

MTN-3334 TLS 1.1. support over https is removed from devices

MTN-3343 Set time manually has been fixed for IP Desk Master V2 devices in Edge and SIP mode

MTN-3352 Issue with headset on IP Desk Master-V2 is now fixed

If headset on the IP Desk Master-V2 was used, the headset would not be detected after use of the handset. This is now fixed.

MTN-3355 The three inputs on the PCB of the IP Desk Master-V2 are now supported