Dynamic group inclusion (Event Type)
From Zenitel Wiki
Event description
Event Owner: | Initiator of group call. |
Event type: | 38 - Dynamic group inclusion |
Subevent: | see list below |
When change to ON: | see list below |
When change to OFF: | see list below |
When related to: | The station/group to include. (dirno). |
Additional information
0 = ON: Station/group is included to the group. (Will also be reported for the initial group) OFF: Station/group is toggled out of the group. (Will also be activated when disconnecting group call) 1 = ON: Group/station snatched by initiator with higher call priority. OFF: ----Not used 2 = ON: Station/group is busy OFF: ----Not used 3 = ON: Station/group is not available, station down, wrong group programming (no stations in the group).??? OFF: ----Not used 4 = ON: Audio active in group OFF: No audio in group 10= ON: ----Not used OFF: Dynamic Group Call end (Used for general cleanup of indication)
Available from alphasys 11.3.x.x