Actions

Nx Witness VMS

From Zenitel Wiki

CEIS icon platf.png

Introduction

Using the ONVIF S and T protocol, Zenitel audio and video intercoms, and IP speakers can be connected to Nx Witness VMS, enabling video and audio streaming, and event triggers. The Zenitel devices can run in any mode (SIP, IC-EDGE, AlphaCom, Zenitel Connect Pro).

Compatibility

The integration has been verified by Network Optix to work with version 6.0.2.40414 and later.

It is recommended that Zenitel devices run on firmware version 9.1.3.4 or later.

Functionality

  • Device discovery
  • Audio and video live streaming
  • Bi-directional audio
  • Audio and video recording
  • Audio playback of pre-recorded messages to Zenitel devices
  • Device digital input triggering events in Nx Witness VMS (Call button press)


Licensing

A camera license is required from Network Optix for each connected intercom.

No license is required from Zenitel for the integration.

Configuration

Set-up and configuration of Zenitel devices

Ensure that ONVIF functions are enabled on the Zenitel device prior to adding them to Nx Witness VMS. The settings are available under Advanced Configuration - Advanced Video.

Recommended ONVIF settings:

Nxwitness6.png
Add devices


Warning icon Uncheck Enable control of relay IDLE state, unless you specifically know how this override works in Nx Witness VMS and what you are using it for. For example, if not unchecked, Nx Witness standard setting causes relay to be constantly activated, meaning door will be constantly unlocked in the Zenitel device.


  • Enable ONVIF Discovery Service means that Nx Witness VMS can search for and discover Zenitel devices on the local network.
  • Report DAK as digital input in ONVIF means that call button push can be used in Nx Witness VMS to create alarm, start recording, open video stream, etc


Set-up and configuration of Nx Witness VMS

Adding Zenitel devices

  • Either let Nx Witness VMS automatically discover the device or manually add it
  • Default user/pass for Zenitel devices: admin/alphaadmin
Nxwitness1.png
Add devices


Enable audio

On each Zenitel device listed go to the camera settings and enable audio.

Nxwitness2.png
Enable audio


Create a new Event Rule for the devices

You can set a number of event rules for Zenitel devices connected, by going into the Camera Rules tab of each device. We recommend as a minimum to set the following rule to get desktop notifications when a call button on the Zenitel devices is pressed:

  • When: Input Signal on Camera
  • At: Device
  • Input ID: automatic
  • Action: Show desktop notification
  • Interval of action: unchecked (instant)
  • To: User
  • Apply the rule
Nxwitness3.png
Event Rules