Actions

Zenitel Connect Pro 1.5 - Release Notes

From Zenitel Wiki

This article provides the release notes for Zenitel Connect Pro running on the ICX-510 hardware or in a Virtual Environment. The release notes for ZCP 1.5.x describe new features, improvements and issues fixed after ICX 1.4.x.

General information

The Zenitel Connect Pro software is available in four different packages:

  • Zenitel_Connect_ICX_1.5.x.swu - Upgrade package for Zenitel Connect Pro running on ICX-510
  • Zenitel_Connect_VMware_1.5.x.zip - Installation package for a fresh install of Zenitel Connect Pro running on VMWare
  • Zenitel_Connect_VBox_1.5.x.zip - Installation package for a fresh install of Zenitel Connect Pro running on Virtual Box
  • Zenitel_Connect_ICX_prod_icx510_1.5.0.zip - Software used for changing an ICX-510 from running ICX-AlphaCom to run Zenitel Connect Pro, or recovery after a system crash.

There is also an excel template file for easy importing: Zenitel Connect Excel Template 1.12

Version 1.5.0

Release info

Name: See "General Information" section
ICX Version: 1.5.0
Date: 05.03.2025
Status: General Availability
Compatibility: Compatible with device software version 9.1.3.2. Compatible with Zenitel PAVA Vipedia-12 running Vipedia SW bundle 5.1.4.0P

New features

  • Possibility to add IP-telephony services in Zenitel Connect Pro
  • Credentials handling has been expanded and updated
  • Added support to initiate Tone test and Button test from Zenitel Connect Pro
  • Communication to devices is now encrypted
  • Reworked logging system and added syslog
  • Node red is released on VM and in preview for ICX 510


Fixes issues

ZEN-866 Could not open door on an AlphaCom station from Zenitel Connect Pro

When the call came from an AlphaCom door station, the door could not always be opened by a Zenitel Connect operator

ZEN-862 When entering an incomplete or wrong PIN code on TEIV-1+ the tone would not time out

The tone will now time out after 4 seconds, and the station will return to idle.

ZEN-823 Users might be logged off after a timeout of 30 minutes

Automatic log off should be after 30 minutes of inactivity. This was 30 minutes after log in. This is now fixed.

ZEN-819 Scanning did not always complete

Scanning for devices would not complete if the page was not in focus. This is fixed.

ZEN-764 Status of a replaced device was "Not Configured" after reassigning dirno of old device

It required a new scan to get the device to show as configured. This is now not necessary anymore.

ZEN-650 Hostname change required reboot

Changing the host name of Zenitel Connect Pro was only visible in the GUI and stored in the database. To make the system use the hostname required a reboot. This is no longer necessary.


Known issues

ZEN-1213 System not stable after restore from 1.4.1

Restoring a backup from earlier release can cause issues, recommend to take a new backup after upgrade

ZEN-1212 Restore on a system with a different IP-address

When restoring a backup the IP address of ZCP needs to be the same as when the backup was done

ZEN-1193 Connect server is not rebooted after factory reset

After a factory reset or upgrade a manual reboot it needed

ZEN-1190 Configuration of display settings for TEIV-1+

It is impossible to configure display settings for TEIV-1+.

ZEN-1145 Syslog server does not receive data from ZCP running on a VM

When syslog is configured, reboot ZCP to make certain that data is sent to the syslog server

ZEN-1108 Adding a second network adapter to a VMWare VM

When a second network adapter is added to an already configured system running on VMware, the original network adapter is no longer available under its configured IP-address. Its configuration becomes ‘Disabled’. The new network becomes Eth0 and has DHCP as configuration.

ZEN-1098 Call forwarding from call queue to IP-telephony destination

Call forwarding of a queued call on time out does not work when the destination should be reached via a IP-Telephony connection

ZEN-619 Default network range reappears after upgrade

For scanning of devices it is possible to add and delete network ranges. For the ICX-510, network range 169.254.0.0/16 is default. After upgrade, this range will re-appear, even when previously deleted.