Actions

Difference between revisions of "VSF-Fortitude8 8.2 Release Notes"

From Zenitel Wiki

(MTN-4354 ENA2060 multicast paging failed in some cases)
(Known Issues)
 
(3 intermediate revisions by the same user not shown)
Line 59: Line 59:
  
 
This does not happen anymore if client sends TEARDOWN command correctly.
 
This does not happen anymore if client sends TEARDOWN command correctly.
 
=== MTN-4339 TFIE loudspeaker gain was low for noisy environments===
 
Increased the MAX config for normal voice on Internal speaker from +18 dB to +21 dB.
 
 
=== MTN-4337 TFIE/TFIX/TFIXv2 headset speaker gain was low for noisy environments===
 
Increased the MAX configuration on Headset speaker from +6 dB to +17 dB.
 
 
Note! This max level is loud and intended for use on heavy noisy environments and when using additional protective ear-plugs.
 
  
 
=== MTN-4329 Fixed an issue with wrong intervals for ONVIF events reports===  
 
=== MTN-4329 Fixed an issue with wrong intervals for ONVIF events reports===  
Line 77: Line 69:
 
There was a problem on Zenitel ONVIF devices that caused software to crash and device to reboot which made Bosch VMS unable to connect to the device.
 
There was a problem on Zenitel ONVIF devices that caused software to crash and device to reboot which made Bosch VMS unable to connect to the device.
  
=== MTN-4189 Added support for Headset to compact stations (TCIS-n)===
 
The headset microphone shall be connected to analogue microphone input connector while Headset speaker is connected on Line-Out 1Vrms output.
 
A configurable GPI pin will be used to switch between Headset or Open Mode.
 
  
 
<br>
 
<br>
  
 
==Known Issues==
 
==Known Issues==
===MTN-4434 Downgrading to 8.1 or 8.0 SW version after factory reset brings the amplifier into reboot loop===
+
=== MTN-4333 HD-Audio mode not working using digital microphone input===  
Downgrading amplifiers from the 8.2 SW version to the 8.1 or 8.0 SW version after factory resetting them brings them into a reboot loop. Downgrading the amplifier to a 7.5 SW version will work.
+
Audio is distorted when digital microphone is used. Audio is OK if using analogue microphone input
 
+
===MTN-4049 IP Heavy Duty Telephone shows speaker volume setting when in Edge Controller mode===
+
=== MTN-4121  Asterisk discards alternative profiles===  
IP Heavy Duty Telephones do not have a speaker, this has been disabled in the device model. The setting option in Edge Controller mode does not do anything and should be ignored
+
Default setting for ITSV-5 sends 3 types (BP & MP & HP). However, Asterisk discards all but the first profile it receives (HP in this case). Since only the "Baseline profile" is supported on the device the video doesn't load. A workaround to this issue is to select "Baseline profile" as the H.264 profile type on the ITSV-5.  
 
 
===MTN-3489 Downgrading IP_LCM from vsft-6.4.3.0 will cause a reboot loop===
 
If downgrading the IP_LCM from vsft-6.4.3.0 to an earlier version, the IP_LCM will go into a reboot loop. Workaround is to factory reset the IP_LCM just after downgrading.
 
 
 
===MTN-3299 TLS Private Keys not restored on Turbine stations===
 
In case that TLS Private Keys are deleted from Turbine station, the only way to restore them is to manually upload them to the station. Factory reset or station upgrade will not restore TLS Private Keys.
 
 
===MTN-2692 Turbine stations won't register to ICX500 or AlphaCom if the dash symbol is not removed from the Directory Number field.===
 
In an unconfigured Turbine station there is a dash character in the Directory Number field in the "Main Settings menu. This dash symbol must be removed when the directory number is entered, else the station will fail to register.
 
 
===MTN-2686 Outputs not working for Exigo amplifiers in SIP mode===
 
GPO's does not work when exigo amplifiers are in SIP mode.
 
 
===MTN-2363 Factory reset does not delete uploaded Script===
 
All uploaded scripts should also be removed on Factory reset
 
 
===MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream===
 
H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.
 
 
===MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR===
 
RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream
 
 
===MTN-2360 Client side forwarding does not work in SIP mode===
 
Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.
 
 
===MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer===
 
Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert
 
 
===MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.===
 
When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.
 
 
===MTN-2356 SNMP not working properly on TCIV under high CPU load===
 
SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.
 
 
===MTN-2339 Group call chime is not played on 3rd party SIP stations===
 
Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.
 
 
===MTN-2220 Default SNMP settings issue with firmware downgrade to 4.9===
 
When downgrading from VSFT 4.11+ to 4.9 a factory reset is necessary if user wants to use default SNMP configuration. For custom snmp.conf file, re-upload with a custom snmp.conf file will fix the problem.
 
 
===MTN-1073 Group call fails if system previously configured with ZAP===
 
If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.
 
  
 +
The issue has been reported and documented here: https://issues.asterisk.org/jira/browse/ASTERISK-29182
  
  

Latest revision as of 15:58, 27 May 2024

This document provides the release notes for VSF-Fortitude8 8.2 with incremental bug fix releases. The release notes for VSF-Fortitude8 8.2 describe new features, improvements and issues fixed after VSF-Fortitude8 8.1.3.2.

Release info

Name: VSF-Fortitude8
Description: VSF-Fortitude8 is a firmware for Turbine Plus Intercoms including the following devices: TCIV-2+, TCIV-3+, TCIV-5+, TCIV-6+, TKIV+, TMIV-1+, TEIV-1+ and TEIV-4+.

The firmware is delivered in two different files:

  • vsff8-8.2.3.x - Used for standard in-field upgrades
  • vsff8-prod-8.2.3.x - Used in production- and recovery upgrades.

Version: 8.2.3.0
Date: 24.05.2024
Status: General Availability

VSF-FORTITUDE8 8.2.3.0

Improvements

DS-899 SIP/SDP support for dynamic payload for codec L16x48 (HD-Audio)

Now supporting SIP media attribute L16/48000 with dynamic payload type in range 96..127. Note! The device needs to be configured in “HD-Audio” mode and voice processing (AEC and NC) is not supported.

DS-802 The keypad backlight of TEIV-1+ is now on in idle state

The backlight will be off if the station is in active or false state.

DS-798 Improved digital zoom

Now image is more clear when zooming. Also possible to zoom down to X4.

DS-781 Reversing procedure for call and opening door on TEIV-1+ with keyboard

To make an intercom call, dial the intercom number. To open the door, dial # then PIN code. On earlier firmware versions it was opposite operation (Intercom call: dial # then intercom number. Door Opening: Dial PIN code.)



Fixed Issues

MTN-4435 RTSP stream could stop in some cases

In case of audio issues, RTSP stream would terminate. Now the stream will continue with a moment of silence instead.

MTN-4403 Sound Detection (VAD) levels were not calibrated correct towards configured input

Since major release 7.0 and newer the audio signal levels have been changed, but the the Sound Detection configured levels was not adjusted making threshold levels significantly off, and not as on 6.x SW and older.

The dBA configured values are now re-calibrated using a TCIV+ as reference. Measure reference level is 0.5 meter in front of station. A Pink noise signal have been used as test signal. The new values shows to be a few dB more sensitive then older 6.x SW but not significant. Note! This is not fine calibrated per product variant so there might be product variations, but all TCIS/TCIV/TFIE should be close in levels.

MTN-4394 Multicast paging working again on intercom devices

Multicast paging was not working on intercom devices when configuring from the webpage. This is now fixed.

MTN-4362 Fixed wrong description in Sound Detection settings

The description of “Minimum time before reactivation” is corrected to “Choose how long to wait before enabling VAD after triggering the DAK key”

MTN-4340 ONVIF backchannel could cut last second of audio

In some cases backchannel could cut around last second of audio when using push to talk or pre-recorded messages that terminate backchannel session.

This does not happen anymore if client sends TEARDOWN command correctly.

MTN-4329 Fixed an issue with wrong intervals for ONVIF events reports

Fixed an issue with wrong parsing of some PullMessages parameters. In some VMSs, PullMessages parameters Timeout and MessageLimit were not parsed correctly on VS-IS8.0.3.2 and wrong values were used.

MTN-4320 Weak cipher suites no longer supported on devices

Removed the AES128-SHA AES128-SHA256:ECDHE-RSA-AES128-SHA:ECDHE-RSA-AES256-SHA:CAMELLIA128-SHA:CAMELLIA256-SHA ciphers reported by security scanner

MTN-4228 Turbine devices could not be used with Bosch VMS

There was a problem on Zenitel ONVIF devices that caused software to crash and device to reboot which made Bosch VMS unable to connect to the device.



Known Issues

MTN-4333 HD-Audio mode not working using digital microphone input

Audio is distorted when digital microphone is used. Audio is OK if using analogue microphone input

MTN-4121 Asterisk discards alternative profiles

Default setting for ITSV-5 sends 3 types (BP & MP & HP). However, Asterisk discards all but the first profile it receives (HP in this case). Since only the "Baseline profile" is supported on the device the video doesn't load. A workaround to this issue is to select "Baseline profile" as the H.264 profile type on the ITSV-5.

The issue has been reported and documented here: https://issues.asterisk.org/jira/browse/ASTERISK-29182