Actions

Difference between revisions of "VSF-Fortitude8 8.2 Release Notes"

From Zenitel Wiki

(VSF-FORTITUDE8 8.1.3.1)
(VSF-FORTITUDE8 8.2.3.0)
Line 18: Line 18:
  
 
=VSF-FORTITUDE8 8.2.3.0=
 
=VSF-FORTITUDE8 8.2.3.0=
 +
==Improvements==
 +
===MTN-4156 Added option for using Normally Closed switch on I/O Pins configured as input===
 +
The default input configuration is Normally Open and the switch contact needs to close to activate the function. A new option “Input NC” has been added to the I/O Pin configuration, which inverts the default behavior and the function is activated on switch open.
 +
 +
<br>
 +
 +
 
==Fixed Issues==
 
==Fixed Issues==
 
=== MTN-4420 Cyber security update===  
 
=== MTN-4420 Cyber security update===  

Revision as of 15:53, 27 May 2024

This document provides the release notes for VSF-Fortitude8 8.2 with incremental bug fix releases. The release notes for VSF-Fortitude8 8.2 describe new features, improvements and issues fixed after VSF-Fortitude8 8.1.3.2.

Release info

Name: VSF-Fortitude8
Description: VSF-Fortitude8 is a firmware for Turbine Plus Intercoms including the following devices: TCIV-2+, TCIV-3+, TCIV-5+, TCIV-6+, TKIV+, TMIV-1+, TEIV-1+ and TEIV-4+.

The firmware is delivered in two different files:

  • vsff8-8.2.3.x - Used for standard in-field upgrades
  • vsff8-prod-8.2.3.x - Used in production- and recovery upgrades.

Version: 8.2.3.0
Date: 24.05.2024
Status: General Availability

VSF-FORTITUDE8 8.2.3.0

Improvements

MTN-4156 Added option for using Normally Closed switch on I/O Pins configured as input

The default input configuration is Normally Open and the switch contact needs to close to activate the function. A new option “Input NC” has been added to the I/O Pin configuration, which inverts the default behavior and the function is activated on switch open.



Fixed Issues

MTN-4420 Cyber security update

A software update to mitigate a critical cyber security issue

Known Issues

MTN-4333 HD-Audio mode not working using digital microphone input

Audio is distorted when digital microphone is used. Audio is OK if using analogue microphone input

MTN-4121 Known issue: Asterisk discards alternative profiles

Default setting for ITSV-5 sends 3 types (BP & MP & HP). However, Asterisk discards all but the first profile it receives (HP in this case). Since only the "Baseline profile" is supported on the device the video doesn't load. A workaround to this issue is to select "Baseline profile" as the H.264 profile type on the ITSV-5.

The issue has been reported and documented here: https://issues.asterisk.org/jira/browse/ASTERISK-29182