Difference between revisions of "Turbine 4.7 - Release notes"
From Zenitel Wiki
(→VSIS-1146 Turbine and INCA fail in AlphaCom with Relay Multicast) |
(→VSIS-431 SNMP Informs support added) |
||
Line 19: | Line 19: | ||
===VSIS-431 SNMP Informs support added=== | ===VSIS-431 SNMP Informs support added=== | ||
− | + | IP stations now support using SNMP Informs for integration with network management systems. | |
===VSIS-432 Turbine address book editing on StationWeb=== | ===VSIS-432 Turbine address book editing on StationWeb=== |
Revision as of 11:51, 20 September 2017
Contents
- 1 VSF-Turbine 4.7
- 1.1 Release info
- 1.2 New Features
- 1.2.1 MTN-1160 Activate ringlist from address book
- 1.2.2 VSIS-217 External feed of audio to the local intercom station on input action
- 1.2.3 VSIS-431 SNMP Informs support added
- 1.2.4 VSIS-432 Turbine address book editing on StationWeb
- 1.2.5 VSIS-433 Turbine address book CSV file download and upload
- 1.2.6 VSIS-441 License policing for IP Stations in SIP mode removed
- 1.2.7 VSIS-460 Pulse support for 64 stations
- 1.2.8 VSIS-489 Virtual I/O script start of digital input
- 1.2.9 VSIS-504 Line-out stream control from microphone
- 1.2.10 VSIS-585 Pulse Group Call and 3rd party SIP phones
- 1.2.11 VSIS-617 TCIx-6 default call destination
- 1.2.12 VSIS-693 Ringlist expanded to 30 entries with individual timeout option
- 1.2.13 VSIS-698 Advance network settings enabled in Pulse mode
- 1.2.14 VSIS-738 Automatic Volume Control enhancements
- 1.2.15 VSIS-798 New Pulse licensing
- 1.2.16 VSIS-831 Volume control from DAK or Input
- 1.2.17 VSIS-1149 Pulse server directory configuration - station selection
- 1.2.18 VSIS-1174 Mass configuration of 802.1x settings from VS-IMT
- 1.2.19 VSIS-1176 Pulse Multi-Subnet support
- 1.2.20 VSIS-1177 ECPIR-3P with EBMDR-8 as Pulse Master station
- 1.2.21 VSIS-1178 Turbine Audio messaging for Pulse and SIP
- 1.2.22 VSIS-1179 Turbine Multi-Conferencing for AlphaCom
- 1.2.23 VSIS-1182 TCIV 4:3 full frame resolution
- 1.2.24 VSIS-1183 TCIV Low-light image performance improvements
- 1.2.25 VSIS-1184 Turbine Firmware for TFIE-6
- 1.2.26 VSIS-1185 Pulse integration with iPBX systems
- 1.2.27 VSIS-1187 TCIV video delay optimizations
- 1.2.28 VSIS-1189 New PTT functions
- 1.2.29 VSIS-1190 Relay control from Web Call and ZAP
- 1.2.30 VSIS-1191 SIP and Pulse new DAK actions
- 1.2.31 VSIS-1192 Inputs As Key Matrix
- 1.2.32 VSIS-1193 Special SIP headers support
- 1.3 Bugfixes and Improvements 4.7.2.4
- 1.3.1 MTN-696 Selectable group call chime in Pulse
- 1.3.2 MTN-845 Turbine with Static IP failed to upgrade from different subnet
- 1.3.3 MTN-890 VAD control from AlphaCom through $DIP doesn't work on Turbine
- 1.3.4 MTN-918 "Line out source: Microphone" setting does not work, option is missing in SIP/Pulse
- 1.3.5 MTN-1049 Relay idle setting doesn't take effect immediately
- 1.3.6 MTN-1061 Web call on Turbine should also handle Incoming/Ringing call
- 1.3.7 MTN-1107 802.1x certificate does not survive a software upgrade
- 1.3.8 MTN-1165 Wrong MAC shown after loading XML backup on Turbine
- 1.3.9 MTN-1196 TCIV rebooting when connected to CCTV server
- 1.3.10 MTN-1230 Multicast for Turbine Stations with onboard switch (TFIE, TKIE and ECPIR) fails
- 1.3.11 VSIS-318 License grace period expiration warning on StationWeb
- 1.3.12 VSIS-704 Group call should use caller codec
- 1.3.13 VSIS-749 TCIV in reboot loop when camera module upgrade takes > 1min
- 1.3.14 VSIS-819 Hide unsupported DAK functions on substations
- 1.3.15 VSIS-1158 TMIS Factory Reset from Frontboard
- 1.3.16 VSIS-1162 Disable Call functions on DAKs when Idle function does not support it
- 1.3.17 VSIS-1163 Turbine in SIP/Pulse mode does not read ipaddress if DAK is set to call ringlist
- 1.3.18 VSIS-1165 Added Video setup mode - Cisco
- 1.3.19 VSIS-1172 ECPIR-3P DAK LED notification has been improved
- 1.3.20 VSIS-1173 TCIV Video is now enabled by default
- 1.4 Security and Improvements 4.7.2.4
- 1.4.1 VSIS-840 Security issue: SSL Certificate Weak Public Key Strength on Turbine/INCA
- 1.4.2 VSIS-841 Security issue: SSL Weak Protocol Version Supported on Turbine/INCA
- 1.4.3 VSIS-842 Security issue: SSLv3 Fallback Vulnerability (POODLE) on Turbine/INCA
- 1.4.4 VSIS-882 Security issue: SSL 64-bit Block Size Cipher Suites Supported (SWEET32)
- 1.5 Known Issues 4.7.2.4
- 1.5.1 MTN-268 Relay follow M-key cannot handle quick M
- 1.5.2 MTN-323 Noise from wind on TCIS
- 1.5.3 MTN-408 802.1X config not properly handling special characters in password
- 1.5.4 MTN-552 PULSE: (Re)Registration of SIP phones takes a long time
- 1.5.5 MTN-598 INCA station fails to register if Hebrew name is too long
- 1.5.6 MTN-1073 Group call fails if system previously configured with ZAP
- 1.5.7 MTN-1077 Lamp test not functioning on ECPIR-3P and belonging EBMDR-8
- 1.5.8 VSIS-878 Factory reset does not delete uploaded Script
- 1.5.9 VSIS-1146 Turbine and INCA fail in AlphaCom with Relay Multicast
- 1.5.10 VSIS-1196 Answer Group Call doesn't work with Answer Call function
VSF-Turbine 4.7
Release info
Name: VSF-Turbine
Description: VSF-Turbine is a firmware archive for all Turbine Family Intercom stations including devices:
TCIS-x, TKIS-2, TCIV-x, TMIS-x, TFIE-x, TKIE-x, TFIX-x, ECPIR-3P and Exigo IP speakers..
The firmware is delivered in two different ZIP archives:
- sti-4.7.2.4 - Used for standard in-field upgrades
- sti-prod-4.7.2.4 - Used in production and upgrades from early software version (tsi-3.0)
Version: 4.7.2.4
Date: 15.09.2017
Status: Limited Availability
New Features
MTN-1160 Activate ringlist from address book
Now it is possible to configure a ring list as an Address Book entry
VSIS-217 External feed of audio to the local intercom station on input action
Use Line in to the Intercom station so that the audio from the aux input is broadcast from the intercom speaker during idle. When a call is made, the intercom audio would then be a higher priority and mute the aux audio.
VSIS-431 SNMP Informs support added
IP stations now support using SNMP Informs for integration with network management systems.
VSIS-432 Turbine address book editing on StationWeb
Address book can now be edited directly on station web. Up to 50 entries.
VSIS-433 Turbine address book CSV file download and upload
It is now possible to both upload and download a CSV file that contains Turbine address book entries. This is possible from both StationWeb and VS-IMT
VSIS-441 License policing for IP Stations in SIP mode removed
No license required for SIP mode IP stations when connecting towards 3rd party servers
VSIS-460 Pulse support for 64 stations
Pulse now supports total of 64 Vingtor-Stentofon IP stations to be auto-discovered, upgraded, configured and registered.
VSIS-489 Virtual I/O script start of digital input
Added support for script execution on the digital input event
VSIS-504 Line-out stream control from microphone
Line-out stream can now be configured with mic signal before or after the Acoustic Echo Canceler. When set before AEC, there will be no signal processing done. Wen set to after AEC, both Open mode with Noise reduction and Full Duplex with PTT control are supported.
VSIS-585 Pulse Group Call and 3rd party SIP phones
Pulse Group call is now fully supported on 3rd party SIP stations that have support for IP multicast paging. Group call can be both received and sent from 3rd party SIP phones.
VSIS-617 TCIx-6 default call destination
Bell button is now acting as DAK key and will call default number without contact being selected from address book.
VSIS-693 Ringlist expanded to 30 entries with individual timeout option
It is now possible to use up to 30 ringlist entries and add a timeout using special option. Example configuration for ringing timer of 20 seconds: 100;ringing_timer=20
VSIS-698 Advance network settings enabled in Pulse mode
Enabled Advanced network settings (802.1x, SNMP, Firewall) on the StationWeb and VS-IMT, for IP stations in Pulse mode.
VSIS-738 Automatic Volume Control enhancements
AVC algorithm basic principle is using one or more mic(s) to measure the ambient audio/noise level and compensate speaker output gain raising Sound Pressure level (SPL) with increasing ambient audio level. AVC can switch to Robust Duplex when speaker level is increased above certain threshold.
VSIS-798 New Pulse licensing
New Licensing for Pulse system introduced. See documentation for more info. Note: both Pulse clients and Pulse server need to be upgraded for new Pulse licensing system to work. E.g. a combination of clients with new firmware and server with previous firmware can cause licence policing issues.
VSIS-831 Volume control from DAK or Input
DAK keys or Inputs can now be used as volume controls in SIP and Pulse mode
VSIS-1149 Pulse server directory configuration - station selection
It is now possible to select which station will be configured in Pulse server directory configuration by checking/un-checking checkbox next to them.
VSIS-1174 Mass configuration of 802.1x settings from VS-IMT
Added functionality in the VS-IMT to handle 802.1x network security settings for multiple stations at once. Both settings and security certificates (PKI) can be handled for many stations at once.
VSIS-1176 Pulse Multi-Subnet support
Pulse system can now be deployed in multiple LAN subnets. Pulse auto-discovery, configuration, upgrade, registration and Group Call is fully supported across multiple LAN segments.
VSIS-1177 ECPIR-3P with EBMDR-8 as Pulse Master station
ECPIR-3P is now a Pulse Master station with some advanced call handling capabilities like call on hold, call queuing, transfer, call stand-by, group call, etc. Up to 4 EBMDR-8 DAK extension panels can be configured. The LEDs are programmed to signal different call actions and statuses.
VSIS-1178 Turbine Audio messaging for Pulse and SIP
Turbine stations now support playing of recorded audio messages on specific Call, Relay/Output, and DTMF events. Messages can play out to speaker or speaker + mic, and can play continuously. Audio files can be uploaded using StationWeb or VS-IMT (mass-upload).
VSIS-1179 Turbine Multi-Conferencing for AlphaCom
Added multi-channel conferencing functionality as both mixing audio source and audio mixer station. Up to 6 mixing channels are supported.
VSIS-1182 TCIV 4:3 full frame resolution
Added a new 960p resolution for H.264 with a 4:3 full frame scale
VSIS-1183 TCIV Low-light image performance improvements
Implemented TCIV improvements for image performance for very low-light environment conditions.
VSIS-1184 Turbine Firmware for TFIE-6
Implemented software support for new TFIE-6 industrial display IP station with a menu navigation, address book and DAK keys. Support for AlphaCom, Pulse and SIP.
VSIS-1185 Pulse integration with iPBX systems
Pulse integration capabilities with AlphaCom and SIP based iPBX systems (e.g. Asterisk). See documentation for details.
VSIS-1187 TCIV video delay optimizations
Optimizations done in video call and stream setup so now there is much less delay for both H.264 and MJPG.
VSIS-1189 New PTT functions
Implemented new default duplex behavior for PTT: press-to-talk, release-to-duplex. New PTT functions like Boost Volume on PTT, override remote PTT, SIP Message Controlled Audio Direction, Mic and Speaker PTT control. See documentation for details.
VSIS-1190 Relay control from Web Call and ZAP
It is now possible to control relays from Web Call interface and ZAP
VSIS-1191 SIP and Pulse new DAK actions
DAK actions for Turbine stations are now extended with more functions: Open Group call, Forwarding, Conversation mode control, Volume control, Call transfer, Hold call, PTT, Call stand-by, and other. See Documentation for details.
VSIS-1192 Inputs As Key Matrix
Inputs As Key Matrix can be used when the user needs more buttons/relays than possible with number of GPIOs on the kits. The GPIs are used s a keyboard matrix to add more DAKs
VSIS-1193 Special SIP headers support
New SIP headers supported: Listen-In call activation, Call priority control, Volume control (per call), Auto-answer (per call)
Bugfixes and Improvements 4.7.2.4
MTN-696 Selectable group call chime in Pulse
In order to use the group call functionality for broadcasting messages through PTT the chime must be possible to deactivate or disabled during such an announcement
MTN-845 Turbine with Static IP failed to upgrade from different subnet
When Turbine is set with static IP address the upgrade will fail when IMT or TFTP server is located in different LAN subnet. This is now fixed with proper gateway handling in barebox (bootloader) environment. NOTE: This will require boot/IMAGE_NAME upgrade to apply fix
MTN-890 VAD control from AlphaCom through $DIP doesn't work on Turbine
Fixed
MTN-918 "Line out source: Microphone" setting does not work, option is missing in SIP/Pulse
Fixed
MTN-1049 Relay idle setting doesn't take effect immediately
Changed Idle relay setting is now applied right away.
MTN-1061 Web call on Turbine should also handle Incoming/Ringing call
Web call now supports answering call, and reports call status correctly.
MTN-1107 802.1x certificate does not survive a software upgrade
Previously uploaded security certificate is being removed with firmware upgrade. For station to successfully authenticate toward 802.1x AAA server, the certificate will need to be uploaded again.
MTN-1165 Wrong MAC shown after loading XML backup on Turbine
Fixed for Turbine. MAC address, host name, hardware type and frontboard (if factory set in /goform/zForm_fact_set) will be correctly set after restore of config file.
MTN-1196 TCIV rebooting when connected to CCTV server
Implemented solution to prevent more then 4 client connections for MJPEG stream 240p and more then 2 for 480p.
MTN-1230 Multicast for Turbine Stations with onboard switch (TFIE, TKIE and ECPIR) fails
Repaired multicast handling in networks that do not have an IGMP querier.
VSIS-318 License grace period expiration warning on StationWeb
Warning is displayed on station web under server monitoring and licensing. Remaining days of grace period are displayed.
VSIS-704 Group call should use caller codec
Only the g722 codec was supported before, so now the call codec is taken from caller
VSIS-749 TCIV in reboot loop when camera module upgrade takes > 1min
If camera module upgrade took longer than 1 minute, TCIV station ended up in reboot loop. This is now fixed.
VSIS-819 Hide unsupported DAK functions on substations
DAK functions which are not supported on substations are no longer shown.
VSIS-1158 TMIS Factory Reset from Frontboard
Key scanner chip was reset after factory reset key press detection
VSIS-1162 Disable Call functions on DAKs when Idle function does not support it
Certain Idle functions do not allow Call function to be set on DAK. For those functions, Call functions are now disabled in station web.
VSIS-1163 Turbine in SIP/Pulse mode does not read ipaddress if DAK is set to call ringlist
The turbine station will now read ipaddress if the station is not registered and the ringlist is not a direct ip call (configured to call number@ipaddress).
VSIS-1165 Added Video setup mode - Cisco
Cisco phones have issue when sending less then 25 fps. Now users can select Cisco mode on StationWeb and video will always be sent in 25 fps. In that case fps parameter on StationWeb will just be related to how many images will be different
VSIS-1172 ECPIR-3P DAK LED notification has been improved
See documentation for more details
VSIS-1173 TCIV Video is now enabled by default
Mode is MJPEG with 480p and 15fps.
Security and Improvements 4.7.2.4
VSIS-840 Security issue: SSL Certificate Weak Public Key Strength on Turbine/INCA
Security scanner detected that SSL certificates are using weak public key strength. Key length has been increased to 2048.
VSIS-841 Security issue: SSL Weak Protocol Version Supported on Turbine/INCA
Security scanner detected support for old versions of SSL. There are now disabled.
VSIS-842 Security issue: SSLv3 Fallback Vulnerability (POODLE) on Turbine/INCA
Security scanner detected SSLv3 Fallback Vulnerability (POODLE). This is now fixed.
VSIS-882 Security issue: SSL 64-bit Block Size Cipher Suites Supported (SWEET32)
Security scanner detected support for weak 64-bit block size ciphers that could be compromised. Those are now disabled in the system.
Known Issues 4.7.2.4
MTN-268 Relay follow M-key cannot handle quick M
Relay configured to follow M-key does not handle quick press on M-key
MTN-323 Noise from wind on TCIS
Wind may cause powerful acoustic signal on mic that software is not able to filter and at same time keep clear voice. Workaround is to make mechanical filtering or shielding of wind effect on mic.
MTN-408 802.1X config not properly handling special characters in password
Character like % is not handled in the password input field for 802.1x.
MTN-552 PULSE: (Re)Registration of SIP phones takes a long time
Long (re)registration times observed on Divus SIP client and SNOM phone. If the same SIP phone is registered against AlphaCom the process is almost instantaneous.
MTN-598 INCA station fails to register if Hebrew name is too long
More than 12 characters entered causes registration problems
MTN-1073 Group call fails if system previously configured with ZAP
If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.
MTN-1077 Lamp test not functioning on ECPIR-3P and belonging EBMDR-8
Alphacom DAK Lamp test (feature 7874) not implemented on DAK Panel ECPIR-3P and belonging EBMDR-8
VSIS-878 Factory reset does not delete uploaded Script
All uploaded scripts should also be removed on Factory reset
VSIS-1146 Turbine and INCA fail in AlphaCom with Relay Multicast
Multicast fails when Turbine and INCA listen to audio program over Relayed Subnet (AlphaCom environment)
VSIS-1196 Answer Group Call doesn't work with Answer Call function
When Answer Group Call is used with Answer/End Call action it works OK (workaround).