Difference between revisions of "VSIS-4.9 Release"
From Zenitel Wiki
(→Major new InterCom features) |
|||
Line 16: | Line 16: | ||
== Major new InterCom features == | == Major new InterCom features == | ||
− | *'''Multicast IP paging for SIP'''<br>Turbine and INCA IP intercom stations and IP speakers now support IP multicast audio when configured in SIP mode. Up to 10 multicast IP addresses can be configured. | + | *'''Multicast IP paging for SIP'''<br>Turbine and INCA IP intercom stations and IP speakers now support [[Multicast Paging (SIP)|IP multicast audio when configured in SIP mode]]. Up to 10 multicast IP addresses can be configured. |
*'''Virtual I/O script execution based on input status change'''<br>Added possibility to enable/disable functions like DAK key action (e.g., make a call) according to a state change on certain input. Use cases: disabling intercom for non-authorized personnel using a badge-reader or denying intercom calls without a vehicle in front of the station (detected by a megnetic loop into the ground). | *'''Virtual I/O script execution based on input status change'''<br>Added possibility to enable/disable functions like DAK key action (e.g., make a call) according to a state change on certain input. Use cases: disabling intercom for non-authorized personnel using a badge-reader or denying intercom calls without a vehicle in front of the station (detected by a megnetic loop into the ground). | ||
*'''Advanced Turbine AVC settings on StationWeb'''<br>Added advanced AVC settings on Turbine StationWeb for AVC algorithm parametrization. These options should be used only in cases when the default AVC behavior needs to be fine-tuned and when the technician has a good understanding about the AVC technology. | *'''Advanced Turbine AVC settings on StationWeb'''<br>Added advanced AVC settings on Turbine StationWeb for AVC algorithm parametrization. These options should be used only in cases when the default AVC behavior needs to be fine-tuned and when the technician has a good understanding about the AVC technology. | ||
Line 22: | Line 22: | ||
*'''VS-IMT improvements'''<br>VS-IMT will now display a warning when TCIV is set as a Pulse server, explaining the limitation and workaround. All DAK actions are now enabled for all Turbine stations, rather than being filtered by station type. The release also includes [[VS-IMT - Release Notes|many small bug-fixes and improvements]]. | *'''VS-IMT improvements'''<br>VS-IMT will now display a warning when TCIV is set as a Pulse server, explaining the limitation and workaround. All DAK actions are now enabled for all Turbine stations, rather than being filtered by station type. The release also includes [[VS-IMT - Release Notes|many small bug-fixes and improvements]]. | ||
*'''Improvements to the VS-Client'''<br>Added improvements to how the VS-Client manages system resources under a high system resources load, which should prevent any possible audible interruptions. Also improved how the VS-Client takes ownership of audio devices; it could happen that the VS-Client locks an audio device such as a USB headset microphone in exclusive ownership, which can cause issues for other applications; this is now improved within the audio engine. | *'''Improvements to the VS-Client'''<br>Added improvements to how the VS-Client manages system resources under a high system resources load, which should prevent any possible audible interruptions. Also improved how the VS-Client takes ownership of audio devices; it could happen that the VS-Client locks an audio device such as a USB headset microphone in exclusive ownership, which can cause issues for other applications; this is now improved within the audio engine. | ||
− | |||
== New AlphaCom IP Public Address Services == | == New AlphaCom IP Public Address Services == |
Revision as of 11:42, 30 May 2018
All new software and firmware can be downloaded from our Downloads page.
New firmware and Application Software (May 2018)
VSIS is an intercom solution software product package. The package includes:
- Turbine firmware 4.9.3.0: Updated firmware for Turbine generation of intercom devices, ENA amplifiers and Exigo IP speakers.
- INCA firmware 2.8.3.0: Updated firmware for all INCA SoC based Intercom stations.
- SDK for Pulse 1.3.3.0: Updated SDK for Pulse system.
- VS-IMT 1.4.3.3: Updated Intercom Management Tool PC application.
- VS-Client 1.3.3.1: Updated VS-Client
Also released:
- AlphaSys 12.5.3.0: with support for ENA amplifiers. How to upgrade: AMC-IP software upgrade procedure. See also AMC-IP Release Notes.
- AlphaPro 11.7.3.2: including direct link to AlphaWiki for help. For a complete list of bug fixes and functional changes and enhancements, see AlphaPro release notes
Major new InterCom features
- Multicast IP paging for SIP
Turbine and INCA IP intercom stations and IP speakers now support IP multicast audio when configured in SIP mode. Up to 10 multicast IP addresses can be configured. - Virtual I/O script execution based on input status change
Added possibility to enable/disable functions like DAK key action (e.g., make a call) according to a state change on certain input. Use cases: disabling intercom for non-authorized personnel using a badge-reader or denying intercom calls without a vehicle in front of the station (detected by a megnetic loop into the ground). - Advanced Turbine AVC settings on StationWeb
Added advanced AVC settings on Turbine StationWeb for AVC algorithm parametrization. These options should be used only in cases when the default AVC behavior needs to be fine-tuned and when the technician has a good understanding about the AVC technology. - Added support for SIP Early Media during 180-Ringing or 183-Session Progress
Now there is support for playing media during SIP 180-Ringing or SIP 183 Call progress, instead of a locally generated ringing tone. This is a very common setup in iPBX systems where the server generates media to be played during session progress and before call is accepted (e.g., call queued before it is answered). - VS-IMT improvements
VS-IMT will now display a warning when TCIV is set as a Pulse server, explaining the limitation and workaround. All DAK actions are now enabled for all Turbine stations, rather than being filtered by station type. The release also includes many small bug-fixes and improvements. - Improvements to the VS-Client
Added improvements to how the VS-Client manages system resources under a high system resources load, which should prevent any possible audible interruptions. Also improved how the VS-Client takes ownership of audio devices; it could happen that the VS-Client locks an audio device such as a USB headset microphone in exclusive ownership, which can cause issues for other applications; this is now improved within the audio engine.
New AlphaCom IP Public Address Services
AlphaCom has inherited a set of new IP Public Address Services from Exigo. With the new features AlphaCom is able to provide a strong IP PA offering.
The main features and capabilities are:
- Connect Exigo amplifiers to Exigo without use of Exigo system controllers
- Enhanced PA monitoring
- HD audio for background music distribution
Two new license types have been added to AlphaCom. These are ENA Amplifier Channel License and HD Audio License. One ENA Amplifier Channel License per amplifier channel is needed. The HD Audio License is per AlphaCom server.
Read more about the amplifiers on Zenitel.com:
Technical information can also be found here on Alphawiki: