Difference between revisions of "AlphaCom E20"
From Zenitel Wiki
(→Networking) |
|||
(24 intermediate revisions by 7 users not shown) | |||
Line 1: | Line 1: | ||
− | {{ | + | {{obsolete}} |
− | [[ | + | |
+ | This product is discontinued and replaced by [[AlphaCom XE20]] | ||
+ | |||
+ | See also [[AlphaCom Exchange Upgrade]] | ||
+ | |||
+ | |||
+ | [[Image:9620 RS.jpg|thumb|400px|AlphaCom E20]] | ||
== Features == | == Features == | ||
Line 33: | Line 39: | ||
The cabinet has room for installation of totally 20 circuit boards, | The cabinet has room for installation of totally 20 circuit boards, | ||
− | one AMC-IP processor board, one APC program & clock board | + | one [[AMC-IP]] processor board, one [[APC]] program & clock board |
− | and up to 18 feature boards. The exchange also includes a mains | + | and up to 18 feature boards. The exchange also includes a [[APWR Power supply|mains power supply]] and a cooling fan, and a [[Status LED]] indicator. |
− | power supply and a cooling fan. | ||
Several exchanges can be interconnected on AlphaNet over IP, | Several exchanges can be interconnected on AlphaNet over IP, | ||
Line 53: | Line 58: | ||
== Installation == | == Installation == | ||
[[image:AC E20 Installation.jpg|thumb|100px|]] | [[image:AC E20 Installation.jpg|thumb|100px|]] | ||
− | The cabinet is intended for mounting in a 19” rack. It has room for | + | The cabinet is intended for mounting in a 19” rack. It has room for installation of totally 20 circuit boards, one [[AMC-IP]] processor board, one [[APC]] program & clock board and up to 18 feature boards. The exchange also includes a [[APWR Power supply|mains power supply]]. |
− | installation of totally 20 circuit boards, one AMC-IP processor | ||
− | board, one APC program & clock board and up to 18 feature | ||
− | boards. The exchange also includes a mains power supply. | ||
[[image:AC E20 Connection to AlphaCom E20.jpg|thumb|100px|]] | [[image:AC E20 Connection to AlphaCom E20.jpg|thumb|100px|]] | ||
* Up to 4 units may be mounted in one 19” rack if sufficient ventilation is provided. It is recommended to mount a 24 VDC cooling fan module on top of each exchange unit. | * Up to 4 units may be mounted in one 19” rack if sufficient ventilation is provided. It is recommended to mount a 24 VDC cooling fan module on top of each exchange unit. | ||
* The two-pair star wired intercom cables are connected to connection boards on the cabinet DIN rail or in a separate distribution field. | * The two-pair star wired intercom cables are connected to connection boards on the cabinet DIN rail or in a separate distribution field. | ||
− | * Each subscriber line card provides 6 freely programmable Remote Control Outputs (RCO’s). | + | * Each subscriber line card provides 6 freely programmable [[RCO|Remote Control Outputs]] (RCO’s). |
* Two RJ45 Ethernet terminals on the IP filter board are used for IP LAN and WAN communication. | * Two RJ45 Ethernet terminals on the IP filter board are used for IP LAN and WAN communication. | ||
* The serial ports with RS232 and RS422/485 interface are used for interface to equipment using these protocols. | * The serial ports with RS232 and RS422/485 interface are used for interface to equipment using these protocols. | ||
− | * 6 program distribution sources can be connected to the APC board via an optional program connection board. Up to 32 extra programs may be added using AGA boards, 16 programs per board. | + | * 6 program distribution sources can be connected to the [[APC]] board via an optional program connection board. Up to 32 extra programs may be added using [[AGA]] boards, 16 programs per board. |
− | * The optional program connection board has input for 6 Remote Control Inputs (RCI) which can initiate programmed actions. | + | * The optional program connection board has input for 6 [[RCI|Remote Control Inputs]] (RCI) which can initiate programmed actions. |
− | * The exchange is powered from the mains. The power supply APWR runs on 90-270 VAC. | + | * The exchange is powered from the mains. The power supply [[APWR Power supply|APWR]] runs on 90-270 VAC. |
The built-in power supply serves approximately 80 standard stations when all stations are activated (All Call or Alarm Call). If All- or Alarm Call is not to be activated, the exchange may be fully equipped with 102 stations. | The built-in power supply serves approximately 80 standard stations when all stations are activated (All Call or Alarm Call). If All- or Alarm Call is not to be activated, the exchange may be fully equipped with 102 stations. | ||
Line 71: | Line 73: | ||
=== Networking === | === Networking === | ||
[[image:AC E20 Networking.jpg|left|thumb|250px|]] | [[image:AC E20 Networking.jpg|left|thumb|250px|]] | ||
− | [[Category: | + | |
+ | <br /><br /><br /><br /><br /><br /><br /><br /><br /><br /><br /><br /><br /><br /><br /> | ||
+ | |||
+ | === Technical Specifications === | ||
+ | |||
+ | {| border="1" | ||
+ | |- | ||
+ | | width="100pt"|'''Dimensions''' (WxHxD) | ||
+ | | width="100pt"|482 x 265 x 365 mm | ||
+ | |- | ||
+ | |'''Weight''' || 17 kg | ||
+ | |- | ||
+ | |'''Mounting''' || 19" rack | ||
+ | |- | ||
+ | |'''Input voltage''' || 90 - 270 VAC | ||
+ | |- | ||
+ | |'''Power consumption''' || max. 450 W (80 subscribers) | ||
+ | |- | ||
+ | |'''Temperature''' || 0 to +35'C / +32 to +95*F enviroment | ||
+ | |- | ||
+ | |'''Humidity range''' || 10% to 90% RH | ||
+ | |- | ||
+ | |'''Connections''': <br /> Feature cards <br /> Traditional intercom <br /> <br /> Entertainment channels <br /> Remote control outputs <br /> Remote control inputs <br /> Serial port <br /> Serial port <br /> Ethernet | ||
+ | || <br /> 18 slot positions <br /> 80 extensions with one power suply <br /> 102 max. physically <br /> 6 on APC board + 16 per AGA board <br /> 6 per ASLT subscriber board <br /> 6 on APC board <br /> 1x RS232, RJ-45 <br /> 1xRS23/RS422/RS485, RJ-45 <br /> 2x 10/100 Mbps, RJ-45 | ||
+ | |- | ||
+ | |'''Traffic capacity''': <br /> SIP trunks <br /> VolP AlphaNet <br /> Digital trunks <br /> Analogue trunks | ||
+ | || <br /> 30 channels <br /> 30 channels <br /> 32 channels <br /> 6 channels | ||
+ | |- | ||
+ | |'''IP protocols''' <br /><br /> || IP v4 - TCP - UDP - Telnet - FTP - NTP <br /> HTTP 1.1 - Syslog - SNMP v2c - SIP - RTP - <br /> RTCP - VolP AlphaNet - STENTOFON data | ||
+ | |- | ||
+ | |'''Audio technology''' <br /><br /><br /> || High-Resolution 1-Bit Audio - High-Fidelity <br /> 40 Hz - 18.5 kHz - Wideband 7 kHz (G.722) <br /> - Narrowband 3.4 kHz (G.711) - Adaptive Jitter <br /> Buffers - Adaptive Time Synchronization | ||
+ | |- | ||
+ | |'''EMC''' <br /> || Emission: IEC 61000-6-3, IEC 61000-6-4 <br /> Immunity: IEC 61000-6-1, IEC 61000-0-2 | ||
+ | |- | ||
+ | |'''Compliance''' || CE, DNV, Report no. 97-1341, EN 60950 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | [[Category:Discontinued Servers]] |
Latest revision as of 13:32, 14 June 2018
This product is discontinued and replaced by AlphaCom XE20
See also AlphaCom Exchange Upgrade
Features
- Next generation multiservice platform with integrated media processing engine, packet processing engine, HW encryption and storage module
- Made for critical communication and security solutions
- Embedded real time Linux operating system
- Best of both worlds – supports a mix of IP and traditional services within the same node
- Backward compatible
- SIP interoperability with VoIP systems and equipment
- Wide range of open interfaces
- Superb audio quality in all environments
- New services through Web i.e. remote programming
- Networking capabilities to extend your solution geographically
Description
The AlphaCom E combines the best of the present advanced AlphaCom system with the latest IP, Linux and embedded networking technologies. When entering the IP world, no compromise has been made. The AlphaCom E provides the complete set of existing services, quality, reliability and security characteristics for which AlphaCom has always been recognized.
Some of the special features it brings into the IP domain are wideband (7 kHz) audio, a built-in firewall, integrated Web and SIP server, hardware encryption and low latency switching.
In addition to these important characteristics, a new set of innovative services has been introduced to improve cost efficiency, service capabilities and system operation.
The cabinet has room for installation of totally 20 circuit boards, one AMC-IP processor board, one APC program & clock board and up to 18 feature boards. The exchange also includes a mains power supply and a cooling fan, and a Status LED indicator.
Several exchanges can be interconnected on AlphaNet over IP, as well as the traditional methods, both locally and worldwide. All communication and services are available throughout the entire network.
The AlphaCom E-series includes extended integration of different kinds of communication and alarm systems, access control, CCTV, public address, public telephones and a variety of features and solutions that can be added when desired. It is easy to interface to 3rd party systems to create special applications.
The new technology allows remote programming, logging and maintenance via AlphaPro, Syslog and standard web browsers.
Installation
The cabinet is intended for mounting in a 19” rack. It has room for installation of totally 20 circuit boards, one AMC-IP processor board, one APC program & clock board and up to 18 feature boards. The exchange also includes a mains power supply.
- Up to 4 units may be mounted in one 19” rack if sufficient ventilation is provided. It is recommended to mount a 24 VDC cooling fan module on top of each exchange unit.
- The two-pair star wired intercom cables are connected to connection boards on the cabinet DIN rail or in a separate distribution field.
- Each subscriber line card provides 6 freely programmable Remote Control Outputs (RCO’s).
- Two RJ45 Ethernet terminals on the IP filter board are used for IP LAN and WAN communication.
- The serial ports with RS232 and RS422/485 interface are used for interface to equipment using these protocols.
- 6 program distribution sources can be connected to the APC board via an optional program connection board. Up to 32 extra programs may be added using AGA boards, 16 programs per board.
- The optional program connection board has input for 6 Remote Control Inputs (RCI) which can initiate programmed actions.
- The exchange is powered from the mains. The power supply APWR runs on 90-270 VAC.
The built-in power supply serves approximately 80 standard stations when all stations are activated (All Call or Alarm Call). If All- or Alarm Call is not to be activated, the exchange may be fully equipped with 102 stations.
Networking
Technical Specifications
Dimensions (WxHxD) | 482 x 265 x 365 mm |
Weight | 17 kg |
Mounting | 19" rack |
Input voltage | 90 - 270 VAC |
Power consumption | max. 450 W (80 subscribers) |
Temperature | 0 to +35'C / +32 to +95*F enviroment |
Humidity range | 10% to 90% RH |
Connections: Feature cards Traditional intercom Entertainment channels Remote control outputs Remote control inputs Serial port Serial port Ethernet |
18 slot positions 80 extensions with one power suply 102 max. physically 6 on APC board + 16 per AGA board 6 per ASLT subscriber board 6 on APC board 1x RS232, RJ-45 1xRS23/RS422/RS485, RJ-45 2x 10/100 Mbps, RJ-45 |
Traffic capacity: SIP trunks VolP AlphaNet Digital trunks Analogue trunks |
30 channels 30 channels 32 channels 6 channels |
IP protocols |
IP v4 - TCP - UDP - Telnet - FTP - NTP HTTP 1.1 - Syslog - SNMP v2c - SIP - RTP - RTCP - VolP AlphaNet - STENTOFON data |
Audio technology |
High-Resolution 1-Bit Audio - High-Fidelity 40 Hz - 18.5 kHz - Wideband 7 kHz (G.722) - Narrowband 3.4 kHz (G.711) - Adaptive Jitter Buffers - Adaptive Time Synchronization |
EMC |
Emission: IEC 61000-6-3, IEC 61000-6-4 Immunity: IEC 61000-6-1, IEC 61000-0-2 |