Line 7: | Line 7: | ||
* Event 25 is triggered when dialing digits after having called feature 105. %SEV will return the dialled digit | * Event 25 is triggered when dialing digits after having called feature 105. %SEV will return the dialled digit | ||
* [[External Data Input|Event 28 - External Data Input]] is triggered when reciving text on an [[External_Data_Input]]. %SEV tells which EDIO port 1 - 10 the EDI text arrived on. | * [[External Data Input|Event 28 - External Data Input]] is triggered when reciving text on an [[External_Data_Input]]. %SEV tells which EDIO port 1 - 10 the EDI text arrived on. | ||
− | * [[AlphaNet Link (Event Type)|Event 29 - AlphaNet Link]]. %SEV is the remote node number | + | * [[AlphaNet Link (Event Type)|Event 29 - AlphaNet Link]] reports AlphaNet links up or down. %SEV is the remote node number |
− | * [[Station DAK key as RCI (Event Type)| Event 30 - Station DAK key as RCI]]: %SEV will return the DAK key number | + | * [[Station DAK key as RCI (Event Type)| Event 30 - Station DAK key as RCI]] reports DAK keys or inputs activated: %SEV will return the DAK key number or Input number |
* [[Private Ringing Outgoing(Event Type)|Event 33 - Private Ringing Outgoing]]. %SEV will return a number indicating the reason why ringing ended | * [[Private Ringing Outgoing(Event Type)|Event 33 - Private Ringing Outgoing]]. %SEV will return a number indicating the reason why ringing ended | ||
* | * |
Revision as of 10:07, 22 August 2018
- Returns the sub-event number (in decimal format) of the event being processed.
Sub-event value 255 acts as a "wild card", and the main event will be triggered regardless of the sub-event number.
Some EventHandler reports use sub event in addition to the main event type:
- Event 25 is triggered when dialing digits after having called feature 105. %SEV will return the dialled digit
- Event 28 - External Data Input is triggered when reciving text on an External_Data_Input. %SEV tells which EDIO port 1 - 10 the EDI text arrived on.
- Event 29 - AlphaNet Link reports AlphaNet links up or down. %SEV is the remote node number
- Event 30 - Station DAK key as RCI reports DAK keys or inputs activated: %SEV will return the DAK key number or Input number
- Event 33 - Private Ringing Outgoing. %SEV will return a number indicating the reason why ringing ended