+ | [[File:TouchLess ICX.png|thumb|500px|left|Input 1 configured to call number 13 when triggered]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | |||
Configuration of Inputs and Direct Access Keys (DAK) are done in [[Users & Stations (AlphaPro)|AlphaPro]]. <br> | Configuration of Inputs and Direct Access Keys (DAK) are done in [[Users & Stations (AlphaPro)|AlphaPro]]. <br> | ||
Detailed information is found under [[Users & Stations (AlphaPro)#DAK|DAK programming]]. | Detailed information is found under [[Users & Stations (AlphaPro)#DAK|DAK programming]]. | ||
[[Category:Additional equipment]] | [[Category:Additional equipment]] |
Revision as of 14:04, 17 March 2021
The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.
Contents
Highlights
- Input Voltage: 5V
- Available contacts: Normally Open & Normally Closed
- Sensor active time: 0,5 secs
- Operating distance: 15cm
- IP66
Connections
Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.
Color code
- Red - +5 Volt supply
- Brown - 0 Volt supply
- Green - Normally Closed
- Blue - Common
- Purple - Normally Open
Typical Application
Use Case Examples
Touchless sensor wired to Input 1 on a Turbine station:
Configuration on IC-Edge
To configure the Inputs select Edge Controller > System Configuration > Direct Access Keys.
Select Show/Hide Settings on the station you want to configure:
Configure the Input to Call To a directory number when activated.
More details can be found on Direct Access Key Settings.
Configuration on ICX-AlphaCom
Configuration of Inputs and Direct Access Keys (DAK) are done in AlphaPro.