Difference between revisions of "Touchless sensor (w/ backbox)"
From Zenitel Wiki
(→Configuration on ICX-AlphaCom) |
(→Configuration on ICX-AlphaCom) |
||
Line 41: | Line 41: | ||
=== Configuration on ICX-AlphaCom === | === Configuration on ICX-AlphaCom === | ||
− | TO configure the | + | TO configure the input to call a preconfigured number: |
# Select '''Users & Stations''' | # Select '''Users & Stations''' | ||
− | # ''' | + | # Select the '''intercom station''' with the touchless sensor connected |
# Open the '''DAK''' window | # Open the '''DAK''' window | ||
# Select the tab '''DAK 11-20''' | # Select the tab '''DAK 11-20''' | ||
− | # On DAK 11 (=input 1) enter the '''directory number''' to call when the input is activated | + | # On DAK 11 (= input 1) enter the '''directory number''' to call when the input is activated |
− | |||
[[File:TouchLess ICX.png|thumb|500px|left|Input 1 configured to call number 13 when triggered]] | [[File:TouchLess ICX.png|thumb|500px|left|Input 1 configured to call number 13 when triggered]] | ||
Line 53: | Line 52: | ||
− | + | More information is found under [[Users & Stations (AlphaPro)#DAK|DAK programming]]. | |
− | |||
[[Category:Additional equipment]] | [[Category:Additional equipment]] |
Revision as of 14:24, 17 March 2021
The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.
Contents
Highlights
- Input Voltage: 5V
- Available contacts: Normally Open & Normally Closed
- Sensor active time: 0,5 secs
- Operating distance: 15cm
- IP66
Connections
Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.
Color code
- Red - +5 Volt supply
- Brown - 0 Volt supply
- Green - Normally Closed
- Blue - Common
- Purple - Normally Open
Typical Application
Use Case Examples
Touchless sensor wired to Input 1 on a Turbine station:
Configuration on IC-Edge
To configure the Input select Edge Controller > System Configuration > Direct Access Keys.
Select Show/Hide Settings on the station you want to configure:
Configure the Input to Call To a directory number when activated.
More details can be found on Direct Access Key Settings.
Configuration on ICX-AlphaCom
TO configure the input to call a preconfigured number:
- Select Users & Stations
- Select the intercom station with the touchless sensor connected
- Open the DAK window
- Select the tab DAK 11-20
- On DAK 11 (= input 1) enter the directory number to call when the input is activated
More information is found under DAK programming.