=== Configuration on IC-Edge === | === Configuration on IC-Edge === | ||
− | To configure the Input select '''Edge Controller''' > '''System Configuration''' > '''Direct Access Keys'''. <br> | + | *To configure the Input select '''Edge Controller''' > '''System Configuration''' > '''Direct Access Keys'''. <br> |
− | Select '''Show/Hide Settings''' on the station you want to configure | + | *Select '''Show/Hide Settings''' on the station you want to configure. |
+ | *Configure the '''Input''' to '''Call To''', and enter the directory number to call when activated. | ||
+ | |||
[[File:TouchLess Inp1 Edge.PNG|thumb|500px|left|Input 1 configured to call number 13 when triggered]] | [[File:TouchLess Inp1 Edge.PNG|thumb|500px|left|Input 1 configured to call number 13 when triggered]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | |||
− | |||
More details can be found on [[Direct Access Key & Ringlist Settings (Edge)|Direct Access Key Settings]]. | More details can be found on [[Direct Access Key & Ringlist Settings (Edge)|Direct Access Key Settings]]. |
Revision as of 14:25, 17 March 2021
The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.
Contents
Highlights
- Input Voltage: 5V
- Available contacts: Normally Open & Normally Closed
- Sensor active time: 0,5 secs
- Operating distance: 15cm
- IP66
Connections
Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.
Color code
- Red - +5 Volt supply
- Brown - 0 Volt supply
- Green - Normally Closed
- Blue - Common
- Purple - Normally Open
Typical Application
Use Case Examples
Touchless sensor wired to Input 1 on a Turbine station:
Configuration on IC-Edge
- To configure the Input select Edge Controller > System Configuration > Direct Access Keys.
- Select Show/Hide Settings on the station you want to configure.
- Configure the Input to Call To, and enter the directory number to call when activated.
More details can be found on Direct Access Key Settings.
Configuration on ICX-AlphaCom
TO configure the input to call a preconfigured number:
- Select Users & Stations
- Select the intercom station with the touchless sensor connected
- Open the DAK window
- Select the tab DAK 11-20
- On DAK 11 (= input 1) enter the directory number to call when the input is activated
More information is found under DAK programming.