Actions

Difference between revisions of "Touchless sensor (w/ backbox)"

From Zenitel Wiki

(Configuration in ICX-AlphaCom)
(Configuration in ICX-AlphaCom)
Line 51: Line 51:
 
<br style="clear:both;" />  
 
<br style="clear:both;" />  
  
(*) Input 1 - 6 is mapped to DAK 11 - 16.
+
(*) Input 1 - 6 on Turbine stations are mapped to DAK 11 - 16.
  
 
More information is found under [[Users & Stations (AlphaPro)#DAK|DAK programming]].
 
More information is found under [[Users & Stations (AlphaPro)#DAK|DAK programming]].
  
 
[[Category:Additional equipment]]
 
[[Category:Additional equipment]]

Revision as of 14:33, 17 March 2021

Touchless sensor, item 2390020100

The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.

Highlights

  • Input Voltage: 5V
  • Available contacts: Normally Open & Normally Closed
  • Sensor active time: 0,5 secs
  • Operating distance: 15cm
  • IP66

Connections

Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.

Color code

  • Red - +5 Volt supply
  • Brown - 0 Volt supply
  • Green - Normally Closed
  • Blue - Common
  • Purple - Normally Open

Typical Application

Touchless sensor - general wiring


Use Case Examples

Touchless sensor wired to Input 1 on a Turbine station:

Touchless sensor - wiring example


Configuration on IC-Edge

  • To configure the Input select Edge Controller > System Configuration > Direct Access Keys.
  • Select Show/Hide Settings on the station you want to configure.
  • Configure the Input to Call To, and enter the directory number to call when activated.
Input 1 configured to call number 13 when triggered


More details can be found on Direct Access Key Settings.

Configuration in ICX-AlphaCom

To configure the input to call a preconfigured number:

  1. Select Users & Stations
  2. Select the intercom station to which the touchless sensor is connected
  3. Open the DAK window
  4. Select the tab DAK 11-20
  5. On DAK 11 (= input 1(*)) enter the directory number to call when the input is activated
Input 1 configured to call number 13 when triggered


(*) Input 1 - 6 on Turbine stations are mapped to DAK 11 - 16.

More information is found under DAK programming.