Difference between revisions of "Turbine 6.1 - Release notes"
From Zenitel Wiki
(→Improvements - Turbine Intercom) |
(→MTN-1045 Disable scrolling while in call) |
||
Line 62: | Line 62: | ||
=== MTN-1045 Disable scrolling while in call=== | === MTN-1045 Disable scrolling while in call=== | ||
Stations which have address book and scroll buttons are no longer able to use those buttons while there's an active, incoming or outgoing call. | Stations which have address book and scroll buttons are no longer able to use those buttons while there's an active, incoming or outgoing call. | ||
+ | |||
+ | <br> | ||
== Improvements - Exigo Amplifiers == | == Improvements - Exigo Amplifiers == |
Revision as of 15:48, 8 April 2021
Contents
- 1 Release info
- 2 VSF-TURBINE 6.1.3.0
- 2.1 New Features - Turbine Intercom
- 2.2 Improvements - Turbine Intercom
- 2.2.1 TYR-109 Security hardening for TLS connections and Secure SIP
- 2.2.2 MTN-3093 Improved Tone test to combat noisy environment and to be able to use in places with multiple stations in the close vicinity
- 2.2.3 MTN-2852 Frontboard DAK can now be configured to switch to internal speaker while performing PTT.
- 2.2.4 MTN-2770 SNMP now allows subnet 32 in allowed network
- 2.2.5 MTN-2693 Added call monitoring options
- 2.2.6 MTN-2689 Additional information shown for uploaded certificates
- 2.2.7 MTN-2661 Options for adjusting CH1 and CH2 offset gain now visible on both normal and extended turbines.
- 2.2.8 MTN-1045 Disable scrolling while in call
- 2.3 Improvements - Exigo Amplifiers
- 2.4 Fixed issues - Turbine Intercom
- 2.4.1 MTN-2657 Firewall range for RTP is increased
- 2.4.2 MTN-2641 One way audio towards Clearcom SIP phones
- 2.4.3 MTN-2530 Removed C-key enabling of Private/Open mode in SIP/Edge mode
- 2.4.4 MTN-2463 Resolved some Audio Messaging issues.
- 2.4.5 MTN-2444 ONVIF device model for TCIV-5
- 2.4.6 MTN-2435 Group call chime is cut off (IC-EDGE)
- 2.4.7 MTN-2074 TKIE-3 keyboard matrix Vol Up/Down was not working
- 2.4.8 MTN-1301 Busy Override would fail when remote party is busy
- 2.5 Fixed issues - Exigo Amplifiers
- 2.6 Known Issues
- 2.6.1 MTN-2692 Turbine stations won't register to ICX500 or Alphacom if the dash symbol is not removed from the Directory Number field
- 2.6.2 MTN-2686 Outputs not working for Exigo amplifiers in SIP mode
- 2.6.3 MTN-2363 Factory reset does not delete uploaded Script
- 2.6.4 MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream
- 2.6.5 MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR
- 2.6.6 MTN-2360 Client side forwarding does not work in SIP mode
- 2.6.7 MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer
- 2.6.8 MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio
- 2.6.9 MTN-2356 SNMP not working properly on TCIV under high CPU load
- 2.6.10 MTN-2339 Group call chime is not played on 3rd party SIP stations
Release info
This document provides the release notes for VSF-Turbine 6.1 with incremental bug fix releases. The release notes for VSF-Turbine 6.1 describe new features, improvements and issues fixed after VSF-Turbine 5.1.
Name: VSF-Turbine
Description: VSF-Turbine is a firmware archive for all Turbine Family Intercom stations including devices:
TCIS-x, TCIV-x, TKIS-2, TMIS-x, TFIE-x, TKIE-x, TFIX-x, IP-LCM, ECPIR-3P, Exigo IP speakers. Exigo Network Amplifiers (only SIP mode and ICX- AlphaCom mode), and ENA-2060 (only in SIP mode)
The firmware is delivered in a ZIP archive:.
Version:
- vsft-6.1.x.x - Used for standard in-field upgrades
Date: 07.04.2021
Status: General Availability
Compatibility: Pulse to IC-EDGE System
You can upgrade from Pulse (VS-IS 4.x) to IC-EDGE, but the whole system needs to run with the same Turbine software (VS-IS 5/6).
In an IC-EDGE System, INCA intercoms cannot be used as the Edge Controller.
TCIV video intercoms should not be used as the Edge Controller for systems exceeding 4 devices.
IMT 1.5 or newer can be used for station discovery and upgrade but must not be used to configure IC-EDGE.
Pulse to IC-EDGE Licenses
Pulse licenses will be honored in an IC-EGDE System. This means that when you upgrade firmware from VS-IS 4.x to 5.x/6.x your Pulse licenses will work for IC-EDGE.
The number of free VS station licenses has been increased from 16 to 32 in IC-EDGE. This means that you get an additional 16 VS stations to connect to in IC-EDGE |
VSF-TURBINE 6.1.3.0
New Features - Turbine Intercom
MTN-3144 Third button option for hold state.
Added third button option under Direct Access Keys for managing calls that are put on hold. This option is available in SIP and Edge.
MTN-3114 Added functionality to force ringing on both accessory and internal loudspeaker
Force loudspeaker ringing option is available in call settings in all modes. It is disabled by default.
MTN-2956 Whitelist functionality is now added for SIP mode.
If whitelist is enabled on the station callers that are not added to whitelist are rejected.
Improvements - Turbine Intercom
TYR-109 Security hardening for TLS connections and Secure SIP
Security level set to 112 bits of security. As a result RSA, DSA and DH keys shorter than 2048 bits and ECC keys shorter than 224 bits are prohibited. Any ciphersuite using RC4 is also prohibited. SSL version 3 is also not allowed. Compression is disabled.
MTN-3093 Improved Tone test to combat noisy environment and to be able to use in places with multiple stations in the close vicinity
Tone volume is automatically adjusted to suit the ambient noise levels and therefore make it suitable to use it in noisy environment. Further improvement is made for environments like a train where multiple stations are next to each other. This might have caused the intercom with faulty speaker picks up tone from another station doing the test at the same time and wrongly reports success. This is now solved by playing multiple frequency tones.
MTN-2852 Frontboard DAK can now be configured to switch to internal speaker while performing PTT.
This is used as a workaround for issues with headset auto detect. User is able to configure DAK key to send M key as well as switch to internal speaker. This is exposed for TFIX and TFIE stations in call settings of ICX AlphaCom mode.
MTN-2770 SNMP now allows subnet 32 in allowed network
SNMP now allows subnet 32 in allowed network making possible to limit SNMP traffic to only one IP address.
MTN-2693 Added call monitoring options
In SIP mode it is possible to configure SIP OPTIONS timer to monitor established calls. If the remote part in a call is unavailable, the call will automatically be hung up. This option is available in advanced configuration mode. Changed registration handling
The minimum registration time is now 30 seconds. If registration time is configured to be below 60 seconds the registration will fail 15 seconds after initial registration message when the SIP server is not responding.
When station fails to register to a SIP server associated calls which are ringing or queued will now be automatically hung up.
MTN-2689 Additional information shown for uploaded certificates
Uploaded certificates will now show expiry date, issuer and subject.
MTN-2661 Options for adjusting CH1 and CH2 offset gain now visible on both normal and extended turbines.
MTN-1045 Disable scrolling while in call
Stations which have address book and scroll buttons are no longer able to use those buttons while there's an active, incoming or outgoing call.
Improvements - Exigo Amplifiers
Fixed issues - Turbine Intercom
MTN-2657 Firewall range for RTP is increased
Firewall for RTP is increased to UDP ports 61000-62000 to support new AlphaCom audio handling.
MTN-2641 One way audio towards Clearcom SIP phones
There was an issue in SDP rtpmap parsing on Zenitel devices which sometimes caused one way audio. This is now resolved.
MTN-2530 Removed C-key enabling of Private/Open mode in SIP/Edge mode
C-key enabling of private/open mode has been removed. IP Flush master and IP Desktop master can do this in the menu.
MTN-2463 Resolved some Audio Messaging issues.
- When audio messaging was set to play "File then Tone", it would play the message and then go silent and not play the ringing tone.
- Group Call is now excluded from call ringing event.
MTN-2444 ONVIF device model for TCIV-5
ONVIF will now correctly return model type for TCIV-5 stations.
MTN-2435 Group call chime is cut off (IC-EDGE)
When doing group call, the group call chime tone may be cut off right at the end. Issue is fixed.
MTN-2074 TKIE-3 keyboard matrix Vol Up/Down was not working
On the TKIE-3 in AlphaCom mode with keyboard matrix the Volume UP (J9-5 and J9-7) and Volume DOWN (J9-5 and J9-6) was not working. This has been fixed. Other keys are functional.
MTN-1301 Busy Override would fail when remote party is busy
Busy override should now be possible if remote part has dialed digits, is offhook or in emergency group call.
Fixed issues - Exigo Amplifiers
Known Issues
MTN-2692 Turbine stations won't register to ICX500 or Alphacom if the dash symbol is not removed from the Directory Number field
In an unconfigured Turbine station there is a dash character in the Directory Number field in the "Main Settings menu. This dash symbol must be removed when the directory number is entered, else the station will fail to register.
MTN-2686 Outputs not working for Exigo amplifiers in SIP mode
GPO's does not work when exigo amplifiers are in SIP mode.
MTN-2363 Factory reset does not delete uploaded Script
All uploaded scripts should also be removed on Factory reset.
MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream
H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.
MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR
RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream
MTN-2360 Client side forwarding does not work in SIP mode
Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.
MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer
Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki when adding TCIV station to Pelco
MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio
When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.
MTN-2356 SNMP not working properly on TCIV under high CPU load
SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.
MTN-2339 Group call chime is not played on 3rd party SIP stations
Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.