Difference between revisions of "Touchless sensor (w/ backbox)"
From Zenitel Wiki
Line 2: | Line 2: | ||
The '''Touchless sensor''' (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button. | The '''Touchless sensor''' (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button. | ||
− | + | ||
== Highlights == | == Highlights == | ||
* Input Voltage: 5V | * Input Voltage: 5V | ||
Line 9: | Line 9: | ||
* Operating distance: 15cm | * Operating distance: 15cm | ||
* IP66 | * IP66 | ||
− | + | <div style="float:right;"> <youtube width="350" height="210">YD-qGSApQPw</youtube> </div> | |
== Connections == | == Connections == | ||
Connections are made to the switch using the supplied 5 pin plug. <br> | Connections are made to the switch using the supplied 5 pin plug. <br> | ||
Correct orientation of the plug is ensured by the connector locating guides. | Correct orientation of the plug is ensured by the connector locating guides. | ||
+ | |||
=== Color code === | === Color code === | ||
* Red - +5 Volt supply | * Red - +5 Volt supply |
Revision as of 09:15, 3 May 2021
The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.
Contents
Highlights
- Input Voltage: 5V
- Available contacts: Normally Open & Normally Closed
- Sensor active time: 0,5 secs
- Operating distance: 15cm
- IP66
Connections
Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.
Color code
- Red - +5 Volt supply
- Brown - 0 Volt supply
- Green - Normally Closed
- Blue - Common
- Purple - Normally Open
Typical Application
Use Case Examples
Touchless sensor - wiring example:
Configuration on IC-Edge
- To configure the Input select Edge Controller > System Configuration > Direct Access Keys.
- Select Show/Hide Settings on the station you want to configure.
- Configure the Input to Call To, and enter the directory number to call when activated.
More details can be found on Direct Access Key Settings.
Configuration in ICX-AlphaCom
To configure the input to call a preconfigured number:
- Select Users & Stations
- Select the intercom station to which the touchless sensor is connected
- Open the DAK window
- Select the tab DAK 11-20
- On DAK 11 (= input 1(*)) enter the directory number to call when the input is activated
(*) Input 1 - 6 on Turbine stations are mapped to DAK 11 - 16.
More information is found under DAK programming.