Pulsing of RCO (Event Handler): Difference between revisions
From Zenitel Wiki
No edit summary |
No edit summary |
||
| Line 1: | Line 1: | ||
{{ | {{AI}} | ||
===Function required=== | ===Function required=== | ||
A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds. | A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds. | ||
| Line 28: | Line 28: | ||
[[Category:Applications]] | [[Category:AlphaCom Applications]] | ||
[[Category: ICX-AlphaCom Applications]] | |||
Revision as of 12:35, 23 May 2022
Function required
A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds.
Solution
The stations dial an Event Trigger number (feature 85), say number 9533, to pulse the RCO 3 for 5 seconds.
First, assign the stations to UDP group 1.
Second, in AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:
| Event Owner: | Stations w/ UDP Id: 1 |
| Event type: | 15 – Event Trigger |
| When change to: | ON |
| When related to: | Directory Number, Id: 9533 |
| Action: | RCO 3 ON 50 |