Difference between revisions of "Tamper switch"
From Zenitel Wiki
(→For all stations) |
|||
Line 17: | Line 17: | ||
* TAMPER CELL 10 - Text to show in the display of the receiver (101 here) | * TAMPER CELL 10 - Text to show in the display of the receiver (101 here) | ||
− | === For all stations === | + | === For multiple (or all) stations === |
− | In [[AlphaPro]], create | + | In [[AlphaPro]], create the event below, and configure [[UDP group]] 8 as event owner: |
[[file:TamperSwitchEvent.png|500px|thumb|left|Event handler configuration]] | [[file:TamperSwitchEvent.png|500px|thumb|left|Event handler configuration]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> |
Revision as of 14:00, 1 December 2022
The IP Vandal Resistant Substation with TKIE has the possibility to be fitted with a tamper switch. Making it possible to raise an alarm if the station is dismounted from the backbox.
Contents
Configuration
For a single station
In AlphaPro, create this event for the Tamper Switch, setting the substation as the event owner:
Action commands:
$STM L110 L101 U145 'TAMPER CELL 10'
- $STM - Send Text Message command
- L110 - Send from 110
- L101 - Send to 101
- U145 - Priority level 145
- TAMPER CELL 10 - Text to show in the display of the receiver (101 here)
For multiple (or all) stations
In AlphaPro, create the event below, and configure UDP group 8 as event owner:
Action commands:
$STM L%2.dir L101 U145 'TAMPER %1.nam'
Verify that I/O 3 is set as an input
The IP Substation must have I/O number 3 defined as an input (default).
Mounting
Mounting instruction on Tamper Switch for IP Vandal Resistant Substation TKIE
Step 1: Remove the two nylon nuts shown below
Step 2: Attach the supplied spacers
Step 3: Mount the tamper switch board
Step 4: Move the button GND wire from the the TKIE board to the tamper switch board
Step 5: Use the supplied wires to connect GND and Input 3 as shown below