Actions

Difference between revisions of "Flowire FCDC3 - Release Notes"

From Zenitel Wiki

(Interoperability with IMT)
(Issues fixed)
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
== Version 1.0.3.4 (2024-03-15) ==
 +
===Release Info===
 +
*Name: vsf-fcdc3-1.0.3.4.zip
 +
*Description: vsf-fcdc3-1.0.3.4_fs_kernel can be installed on FCDC3
 +
*Version: 1.0.3.4
 +
*Date: 15.03.2024
 +
*Status: GA
 +
* Upgrade: See [[FCDC-3 - Software Upgrade Procedure|Flowire Software Upgrade Procedure]]
 +
 +
'''Files included in vsf-fcdc3-1.0.3.4.zip''':
 +
*'''vsf-fcdc3-1.0.3.4_fs_kernel''' - For upload to web by users.
 +
* '''vsf-fcdc3-1.0.3.4_flash_image_960333PLC_REF.w''' - Complete image for JTAG/SPI burning at production.
 +
 +
<br>
 +
 +
=== Issues fixed ===
 +
====MTN-3793 Monitoring no longer fails to recover====
 +
Fixed monitor recovering after a connection lost.
 +
 +
<br>
 +
 +
=== Important information ===
 +
====Interoperability with TFIX-1/2/3 and FCDC-1/2====
 +
FCDC3 is compatible with FCDC1/2 including TFIX and Exigo Ex Access panels, but only after these devices have been upgraded to software version 4.1.3.13 or newer.  See [[FCDC-3_-_Backwards_compatibility]] for more information. In particular, in clusters with mix of FCDC1/2 and FCDC3, one FCDC3 must be set as "CCo".
 +
 +
====IGMP snooping / multicast====
 +
From vsf-fcdc3-1.0.3.1 IGMP snooping is disabled by default, and add web configuration for enable/disable IGMP snooping. IGMP snooping on FCDC3 only work properly with IGMPv3.
 +
 +
====Interoperability with IMT====
 +
IMT version 1.6.3.0 or newer must be used for upgrading of FCDC3.
 +
 +
<br>
 +
 +
 
== Version 1.0.3.3 (2021-07-06) ==
 
== Version 1.0.3.3 (2021-07-06) ==
 
===Release Info===
 
===Release Info===
Line 11: Line 45:
 
*'''vsf-fcdc3-1.0.3.3_fs_kernel''' - For upload to web by users.
 
*'''vsf-fcdc3-1.0.3.3_fs_kernel''' - For upload to web by users.
 
* '''vsf-fcdc3-1.0.3.3_flash_image_960333PLC_REF.w''' - Complete image for JTAG/SPI burning at production.
 
* '''vsf-fcdc3-1.0.3.3_flash_image_960333PLC_REF.w''' - Complete image for JTAG/SPI burning at production.
 +
 +
<br>
  
 
=== New features ===
 
=== New features ===
==== MTN-3270 Wrong default communication password from production====
 
Devices from production are now able to communicate without a factory reset.
 
 
 
==== MTN-3158 Introduced possibility to reduce output power on the PLC-modem from the web====  
 
==== MTN-3158 Introduced possibility to reduce output power on the PLC-modem from the web====  
 
This option can be used to reduce cross-talk/interference between flowire devices.
 
This option can be used to reduce cross-talk/interference between flowire devices.
Line 22: Line 55:
 
This will help during installation to see if total number of devices can cause communication issues due to too much traffic on the two-wire interface.
 
This will help during installation to see if total number of devices can cause communication issues due to too much traffic on the two-wire interface.
  
 +
<br>
 +
 +
=== Issues fixed ===
 +
==== MTN-3270 Wrong default communication password from production====
 +
Devices from production are now able to communicate without a factory reset.
  
 
For more information about FCDC3 SW and HW visit [[FCDC-3]].
 
For more information about FCDC3 SW and HW visit [[FCDC-3]].
 +
 +
<br>
  
 
=== Known issues ===
 
=== Known issues ===

Latest revision as of 13:25, 22 March 2024

Version 1.0.3.4 (2024-03-15)

Release Info

  • Name: vsf-fcdc3-1.0.3.4.zip
  • Description: vsf-fcdc3-1.0.3.4_fs_kernel can be installed on FCDC3
  • Version: 1.0.3.4
  • Date: 15.03.2024
  • Status: GA
  • Upgrade: See Flowire Software Upgrade Procedure

Files included in vsf-fcdc3-1.0.3.4.zip:

  • vsf-fcdc3-1.0.3.4_fs_kernel - For upload to web by users.
  • vsf-fcdc3-1.0.3.4_flash_image_960333PLC_REF.w - Complete image for JTAG/SPI burning at production.


Issues fixed

MTN-3793 Monitoring no longer fails to recover

Fixed monitor recovering after a connection lost.


Important information

Interoperability with TFIX-1/2/3 and FCDC-1/2

FCDC3 is compatible with FCDC1/2 including TFIX and Exigo Ex Access panels, but only after these devices have been upgraded to software version 4.1.3.13 or newer. See FCDC-3_-_Backwards_compatibility for more information. In particular, in clusters with mix of FCDC1/2 and FCDC3, one FCDC3 must be set as "CCo".

IGMP snooping / multicast

From vsf-fcdc3-1.0.3.1 IGMP snooping is disabled by default, and add web configuration for enable/disable IGMP snooping. IGMP snooping on FCDC3 only work properly with IGMPv3.

Interoperability with IMT

IMT version 1.6.3.0 or newer must be used for upgrading of FCDC3.



Version 1.0.3.3 (2021-07-06)

Release Info

  • Name: vsf-fcdc3-1.0.3.3.zip
  • Description: vsf-fcdc3-1.0.3.3_fs_kernel can be installed on FCDC3
  • Version: 1.0.3.3
  • Date: 06.07.2021
  • Status: GA
  • Upgrade: See Flowire Software Upgrade Procedure

Files included in vsf-fcdc3-1.0.3.3.zip:

  • vsf-fcdc3-1.0.3.3_fs_kernel - For upload to web by users.
  • vsf-fcdc3-1.0.3.3_flash_image_960333PLC_REF.w - Complete image for JTAG/SPI burning at production.


New features

MTN-3158 Introduced possibility to reduce output power on the PLC-modem from the web

This option can be used to reduce cross-talk/interference between flowire devices.

MTN-3157 Possibility to get the "Direct on a different network"-list of stations on the web-page

This will help during installation to see if total number of devices can cause communication issues due to too much traffic on the two-wire interface.


Issues fixed

MTN-3270 Wrong default communication password from production

Devices from production are now able to communicate without a factory reset.

For more information about FCDC3 SW and HW visit FCDC-3.


Known issues

The "Backup/Restore settings" function in the web only include a few of the settings.


Important information

Interoperability with TFIX-1/2/3 and FCDC-1/2

FCDC3 is compatible with FCDC1/2 including TFIX and Exigo Ex Access panels, but only after these devices have been upgraded to software version 4.1.3.13 or newer. See FCDC-3_-_Backwards_compatibility for more information. In particular, in clusters with mix of FCDC1/2 and FCDC3, one FCDC3 must be set as "CCo".

IGMP snooping / multicast

From vsf-fcdc3-1.0.3.1 IGMP snooping is disabled by default, and add web configuration for enable/disable IGMP snooping. IGMP snooping on FCDC3 only work properly with IGMPv3.

Interoperability with IMT

IMT version 1.6.3.0 or newer must be used for upgrading of FCDC3.


Version 1.0.3.2 (2020-03-17)

Release Info

  • Name: vsf-fcdc3-1.0.3.2.zip
  • Description: vsf-fcdc3-1.0.3.2_fs_kernel can be installed on FCDC3
  • Version: 1.0.3.2
  • Date: 17.03.2020
  • Status: GA
  • Upgrade: See Flowire Software Upgrade Procedure

Files included in vsf-fcdc3-1.0.3.2.zip:

  • vsf-fcdc3-1.0.3.2_fs_kernel - For upload to web by users.
  • vsf-fcdc3-1.0.3.2_flash_image_960333PLC_REF.w - Complete image for JTAG/SPI burning at production.

New version vsf-fcdc3-1.0.3.2

vsf-fcdc3-1.0.3.2 is the first version released for General Availability.

vsf-fcdc3-1.0.3.2 fixes interoperability with FCDC1/2 when multiple clusters(MTN-2853).

Several improvements has been made to the web interface. All relevant settings are now listed on the front web page. See Changes.txt in zip file for details.

For more information about FCDC3 SW and HW visit FCDC-3.

Known issues

The "Backup/Restore settings" function in the web only include a few of the settings.


Important information

Interoperability with TFIX-1/2/3 and FCDC-1/2

FCDC3 is compatible with FCDC1/2 including TFIX and Exigo Ex Access panels, but only after these devices have been upgraded to software version 4.1.3.13 or newer. See FCDC-3_-_Backwards_compatibility for more information. In particular, in clusters with mix of FCDC1/2 and FCDC3, one FCDC3 must be set as "CCo".

IGMP snooping / multicast

From vsf-fcdc3-1.0.3.1 IGMP snooping is disabled by default, and add web configuration for enable/disable IGMP snooping. IGMP snooping on FCDC3 only work properly with IGMPv3.

Interoperability with IMT

Upcoming IMT version 1.6.3.0 will support mass upgrade of FCDC3. vsf-fcdc3-1.0.3.0 is the very first version that support mass upgrade from IMT. FCDC3 devices with earlier un-released versions must be manually upgraded via the web.