This document provides the release notes for VSF-Fortitude8 7.4 with incremental bug fix releases. The release notes for VSF-Fortitude8 7.4 describe new features, improvements and issues fixed after VSF-Fortitude8 7.3.3.1.
 
This document provides the release notes for VSF-Fortitude8 7.4 with incremental bug fix releases. The release notes for VSF-Fortitude8 7.4 describe new features, improvements and issues fixed after VSF-Fortitude8 7.3.3.1.
Line 5: Line 6:
 
==Release info==
 
==Release info==
 
'''Name:''' VSF-Fortitude8 <br>
 
'''Name:''' VSF-Fortitude8 <br>
'''Description:''' VSF-Fortitude8 is a firmware for Turbine Plus Intercoms including the following devices:
+
'''Description:''' VSF-Fortitude8 is a firmware for [[Zenitel Devices based on iMX8|Zenitel devices based on the IMX8 processor]].
[[TCIV-2+]], [[TCIV-3+]], [[TCIV-5+]], [[TCIV-6+]], [[TKIV+]] and [[TMIV-1+]]
 
  
 
The firmware is delivered in two different files:
 
The firmware is delivered in two different files:
Line 13: Line 13:
 
*vsff8-prod-7.4.3.x - Used in production- and recovery upgrades.
 
*vsff8-prod-7.4.3.x - Used in production- and recovery upgrades.
  
'''Version:''' 7.3.3.1<br>
+
'''Version:''' 7.4.3.0<br>
'''Date:''' 25.11.2022 <br>
+
'''Date:''' 30.01.2023 <br>
 
'''Status:''' General Availability<br>
 
'''Status:''' General Availability<br>
  
Line 24: Line 24:
 
<br>
 
<br>
  
==Issues fixed==
+
==Improvements==
===MTN-3972 It is now possible to upgrade new products with hardware revision 4 to software vsff8-7.3.3.1 or higher===
+
===MTN-3867 Relay activation is now supported from NxWitness VMS===
Hardware revision 4 can not be upgraded to vsff8-7.3.3.0
+
Added support for <onvifDevice:RelayOutputToken> tag to handle NxWitness implementation.
  
 +
===MTN-3434 SNMP traps are now sent only on registration change state.===
 +
For example a trap will be sent when the devices goes from registered to unregistered (or vice versa), it was previously sent after each registration interval even if there were no changes to the state.
  
 
<br>
 
<br>
  
==Known Issues==
+
==Issues fixed==
=== SUN-476 HTTP MJPEG stream has color distortions when viewed in LenelS2 OnGuard===  
+
=== MTN-4008 Syncing is now properly mapped for Alphacom "Noise Reduction" configuration level 0 to 7===  
HTTP MJPEG stream has color distortions when viewed in LenelS2 OnGuard, recommendation is to use RTSP H.264 for video integration instead.
+
The new configuration "Moderate" was not mapped. New mapping:
 
+
*0: ANC Disabled
=== SUN-349 MJPEG stream shows green image in Avigilon===
+
*1,2: ANC Enabled with Low Suppression
MJPEG stream shows green image in Avigilon, recommendation is to use H.264 for video integration instead.
+
*3,4: ANC Enabled with Moderate Suppression
 
+
*5,6: ANC Enabled with High Suppression
 
+
*7: ANC Enabled with Very High Suppression
<br>
 
  
 +
=== MTN-3958 Changing VoIP port range adds 1000 ports to the start value===
 +
Max port number is 65535, if start value is higher than 64535, remaining ports are allocated.
  
=VSF-FORTITUDE8 7.3.3.0=
+
=== MTN-3952 Added support for disabling factory reset from call button or input===  
==Issues fixed==
+
If the checkbox is enabled it's not possible to factory reset the device via call button or input.
=== MTN-3922 Intercom set to correct device type after software upgrade===  
 
Fixed an issue where intercom would be set as a kit after the upgrade.
 
  
=== MTN-3918 AVC - Default value for Far-end Lockout Time changed to 100 ms. Debug in Display now shows 0 dB===  
+
=== MTN-3951 Loudspeaker volume configuration now applied correctly after reboot===  
Default value for AVC parameter Far-end Lockout Time was set to 1 second. This is now changed to 100 milliseconds.
+
The loudspeaker level after boot was always similar to configuration, about +4dB. A configuration change up and down was needed to get back to configured audio level. The audio level shall now be applied as configured after boot.
Also, Debug in Display wouldn't show correct value for no gain raise, i.e. 0 dBA raise, this is now fixed, and correct 0 dB value is shown.
 
  
=== MTN-3905 Triggering relay via ONVIF in ICX-AlphaCom mode fixed===  
+
=== MTN-3910 Uploaded certificates can now be deleted===  
Fixed an issue which prevented relay being triggered over ONVIF if station is in ICX-AlphaCom mode
+
The deletion of certificates uploaded in the device web was previously not possible. This is now fixed.
  
=== MTN-3882 Fixed DAK function for Volume Control===  
+
=== MTN-3906 Device now waits for the ONVIF subscription timer to run out before deleting subscription===  
When DAK function is set to Volume Control, pressing DAK wouldn't raise or lower the gain. This is now fixed, and volume can be configured also with DAK.
+
Subscription timer for ONVIF messages was running out before the message timer. This is now fixed.
  
=== MTN-3860 ONVIF issue with AMAG Symmetry fixed===  
+
=== MTN-3896 Factory reset audio parameters now affects only Audio Settings page===  
Fixed an issue which prevented station from being added to AMAG Symmetry.
+
Factory reset audio parameters doesn't affect VAD, Tone Test and DAVC settings, only settings which are configured on Audio Settings page.
  
 
<br>
 
<br>
Line 68: Line 68:
 
=== SUN-349 MJPEG stream shows green image in Avigilon===  
 
=== SUN-349 MJPEG stream shows green image in Avigilon===  
 
MJPEG stream shows green image in Avigilon, recommendation is to use H.264 for video integration instead.
 
MJPEG stream shows green image in Avigilon, recommendation is to use H.264 for video integration instead.
 +
 +
 +
<br>
 +
  
  
  
 
[[Category: Release notes]]
 
[[Category: Release notes]]

Latest revision as of 09:20, 21 June 2024

This document provides the release notes for VSF-Fortitude8 7.4 with incremental bug fix releases. The release notes for VSF-Fortitude8 7.4 describe new features, improvements and issues fixed after VSF-Fortitude8 7.3.3.1.

Release info

Name: VSF-Fortitude8
Description: VSF-Fortitude8 is a firmware for Zenitel devices based on the IMX8 processor.

The firmware is delivered in two different files:

  • vsff8-7.4.3.x - Used for standard in-field upgrades
  • vsff8-prod-7.4.3.x - Used in production- and recovery upgrades.

Version: 7.4.3.0
Date: 30.01.2023
Status: General Availability

VSF-FORTITUDE8 7.4.3.0

New Features

MTN-3847 Option to disable registration in SIP mode added

A new option, No-Reg, has been added for Registration Method in Account Settings which will prevent registration towards a server. Device can operate in peer to peer mode.


Improvements

MTN-3867 Relay activation is now supported from NxWitness VMS

Added support for <onvifDevice:RelayOutputToken> tag to handle NxWitness implementation.

MTN-3434 SNMP traps are now sent only on registration change state.

For example a trap will be sent when the devices goes from registered to unregistered (or vice versa), it was previously sent after each registration interval even if there were no changes to the state.


Issues fixed

MTN-4008 Syncing is now properly mapped for Alphacom "Noise Reduction" configuration level 0 to 7

The new configuration "Moderate" was not mapped. New mapping:

  • 0: ANC Disabled
  • 1,2: ANC Enabled with Low Suppression
  • 3,4: ANC Enabled with Moderate Suppression
  • 5,6: ANC Enabled with High Suppression
  • 7: ANC Enabled with Very High Suppression

MTN-3958 Changing VoIP port range adds 1000 ports to the start value

Max port number is 65535, if start value is higher than 64535, remaining ports are allocated.

MTN-3952 Added support for disabling factory reset from call button or input

If the checkbox is enabled it's not possible to factory reset the device via call button or input.

MTN-3951 Loudspeaker volume configuration now applied correctly after reboot

The loudspeaker level after boot was always similar to configuration, about +4dB. A configuration change up and down was needed to get back to configured audio level. The audio level shall now be applied as configured after boot.

MTN-3910 Uploaded certificates can now be deleted

The deletion of certificates uploaded in the device web was previously not possible. This is now fixed.

MTN-3906 Device now waits for the ONVIF subscription timer to run out before deleting subscription

Subscription timer for ONVIF messages was running out before the message timer. This is now fixed.

MTN-3896 Factory reset audio parameters now affects only Audio Settings page

Factory reset audio parameters doesn't affect VAD, Tone Test and DAVC settings, only settings which are configured on Audio Settings page.


Known Issues

SUN-476 HTTP MJPEG stream has color distortions when viewed in LenelS2 OnGuard

HTTP MJPEG stream has color distortions when viewed in LenelS2 OnGuard, recommendation is to use RTSP H.264 for video integration instead.

SUN-349 MJPEG stream shows green image in Avigilon

MJPEG stream shows green image in Avigilon, recommendation is to use H.264 for video integration instead.