'''TA-10''' is a Relay Module to be used with Turbine Industrial stations [[TFIE-1]] and [[TFIE-2]], and the Turbine kits [[TKIE-1]] and [[TKIE-2]].
[[File:1008140100.PNG|thumb|350px|The TA-10 Relay Module (1008140100)]]


===Highlights===
==Highlights==
* Designed for use with Turbine Industrial IP Intercom stations
* Designed for use with Turbine Industrial stations TFIE-x, and the Turbine kits TKIE-x
* Fits inside the TFIE Industrial stations (Bracket is included in the TFIE station)
* Dual high-power relays (DPDT)
* Dual high-power relays (DPDT)
* Up to 400VAC /48 VDC per relay
* Up to 400VAC /48 VDC per relay
* Up to 6A current per relay
* Up to 8A current per relay
* Heavy-duty spring-loaded terminals with spare grounding terminals
* Heavy-duty spring-loaded terminals with spare grounding terminals
* Powered by Turbine Industrial stations (TFIE-x) or Turbine Extended Kit (TKIE-x)
* Powered by Turbine Industrial stations (TFIE-x) or Turbine Extended Kit (TKIE-x)


===Dimensions===
==Connection==
* Use the cable that comes with the TA-10, and connect one end to the Turbine Extended Board (Connector J2), and the other end to the TA-10 board as indicated in the drawing below
[[File:TA10-TFIE Connection.PNG|thumb|left|400px|Connecting the TA-10 Relay Unit to a TFIE station or a TKIE kit]]
<br style="clear:both;" />
 
==Configuration==
[[File:TA-10 RCO map.PNG|right|400px|thumb|Logical RCO 11 is mapped to the relay of the TA-10 unit on station 118]]
'''ICX-AlphaCom Mode''':
* Use the [[AlphaPro]] tool, and go to '''Exchange & System''' > '''RCO'''
* The two relays must be mapped in the RCO table as pin 9 and pin 10
* See [[RCO - Remote Control Output]] for more details
 


{|border="1"
'''SIP or Pulse mode''':
|width="250px"|&nbsp;
* Log on to the web interface of the station
|width="250px"|'''Dimensions (WxHxD)'''
* Select '''SIP Configuration''' > '''Relay Settings''', select '''Relay 3''' or '''Relay 4''', and configure which event should operate the relay
|width="150px"|'''Weight'''
* See [[Relay_Settings_(SIP)|Relay Settings]] for more details
|-
|TA-10 || 100 x 50 x 40 mm || 0.1 kg
|}


===Connections===
==Dimensions==
[[File:TA-10.png|thumb|left|500px|Relay 3 is configured as output 9, and Relay 4 is configured as output 10]]
*'''Dimensions (WxHxD)''': 100 x 50 x 40 mm
<br style="clear:both;" />
*'''Weight''': 0.1 kg


===Additional Documentation===
== Related Information ==
For more documentation please see http://www.zenitel.com/product/product/ta-10
* [http://www.zenitel.com/product/ta-10 Additional Documentation on Zenitel.com]


[[Category: Turbine Backboxes and accessories]]
[[Category: Backboxes and accessories]]

Latest revision as of 12:44, 18 February 2025

AEIPS.png

TA-10 is a Relay Module to be used with Turbine Industrial stations TFIE-1 and TFIE-2, and the Turbine kits TKIE-1 and TKIE-2.

The TA-10 Relay Module (1008140100)

Highlights

  • Designed for use with Turbine Industrial stations TFIE-x, and the Turbine kits TKIE-x
  • Fits inside the TFIE Industrial stations (Bracket is included in the TFIE station)
  • Dual high-power relays (DPDT)
  • Up to 400VAC /48 VDC per relay
  • Up to 8A current per relay
  • Heavy-duty spring-loaded terminals with spare grounding terminals
  • Powered by Turbine Industrial stations (TFIE-x) or Turbine Extended Kit (TKIE-x)

Connection

  • Use the cable that comes with the TA-10, and connect one end to the Turbine Extended Board (Connector J2), and the other end to the TA-10 board as indicated in the drawing below
Connecting the TA-10 Relay Unit to a TFIE station or a TKIE kit


Configuration

Logical RCO 11 is mapped to the relay of the TA-10 unit on station 118

ICX-AlphaCom Mode:


SIP or Pulse mode:

  • Log on to the web interface of the station
  • Select SIP Configuration > Relay Settings, select Relay 3 or Relay 4, and configure which event should operate the relay
  • See Relay Settings for more details

Dimensions

  • Dimensions (WxHxD): 100 x 50 x 40 mm
  • Weight: 0.1 kg