Line 39: | Line 39: | ||
|align=center|3||[[UINT1]]||colspan="3"|Exchange type:<br\>1 = AC <br\>2 = TL | |align=center|3||[[UINT1]]||colspan="3"|Exchange type:<br\>1 = AC <br\>2 = TL | ||
|- | |- | ||
− | |align=center|4||[[UINT1]]||colspan="3"|Station type | + | |align=center|4||[[UINT1]]||colspan="3"|Station type:<br\>0 = Master <br\>1 = Sub <br\>2 = PNCI <br\>3 = CRM3/4 <br\>4 = Interguard <br\>5 = DualDisplay <br\>6 = Custom <br\>7 = SIP |
|- | |- | ||
− | |align=center|5||[[UINT1]]||colspan="3"|Display type <br\>1 = | + | |align=center|5||[[UINT1]]||colspan="3"|Display type <br\>1 = 2 line TL<br\>2 = CRM3/4 |
|- | |- | ||
|align=center|6||[[UINT1]]||colspan="3"|Class of service | |align=center|6||[[UINT1]]||colspan="3"|Class of service |
Revision as of 11:32, 13 August 2007
AUDIO_PATH_SETUP | 0x8001 | 32769 | AMC 06.00 | |
---|---|---|---|---|
AlphaNet: Set up audio path between a source node and a destination node (possibly via transit nodes). <br\>Audio path is needed for a number of exchange features. To speed up things, the feature setup message is included as “payload” of this message. | ||||
1 | UINT1 | Channel number. <br\>0 = request for channel. | ||
2 | UINT1 | Priority<br\>0x00 ... 0x0F | ||
3 | UINT1 | Starting node of audio path. | ||
4 | UINT1 | Ending node of audio path. | ||
5 | UINT1 | Backward local reference for next node | ||
6 | UINT1 | Channel type. <br\>1 = Full duplex audio channel <br\>2 = IP full duplex audio channel. (field 7,8,9 added) | ||
7 | UINT4 | Prev node Audio RTP IP address for next node (AMC 10.00) | ||
8 | UINT2 | Prev node Audio RTP port number for next node (AMC 10.00) | ||
9 | BITMAP[1..32] | Start node AudioCodecs supported. (AMC 10.00)<br\>Bit 1: G711<br\>Bit 2: G722<br\>Bit 3: 32Khz raw PCM <br\>Bit 4: | ||
10 | PAYLOAD | End-to-end message. See below | ||
Response: | AUDIO_LINK_OK <br\>AUDIO_LINK_NOT_AVAILABLE | |||
<br\>PAYLOAD MESSAGE attached to AUDIO PATH SETUP and related messages:<br\> | ||||
1 | UINT1 | Protocol version:<br\>0 = AlphaCom basic functions | ||
2 | UINT1 | Remote function:<br\>1 = Remote proxy station, digits will be dialed later. <br\>3 = Ordinary call identified by Bnumber parameter. <br\>5 = Call to waiting station identified by Bnumber parameter, used for answer calls. <br\>Support for remote functions 3 and 5 is acknowledged in AUDIO_PATH_OK with Bprotocol version set to 1 or higher. | ||
3 | UINT1 | Exchange type:<br\>1 = AC <br\>2 = TL | ||
4 | UINT1 | Station type:<br\>0 = Master <br\>1 = Sub <br\>2 = PNCI <br\>3 = CRM3/4 <br\>4 = Interguard <br\>5 = DualDisplay <br\>6 = Custom <br\>7 = SIP | ||
5 | UINT1 | Display type <br\>1 = 2 line TL<br\>2 = CRM3/4 | ||
6 | UINT1 | Class of service | ||
7 | UINT1 | Group call access level | ||
8 | UINT1 | Call priority | ||
9 | BITMAP[1..16] | Flags describing station and its configuration:<br\>bit 1: Handset_off<br\>bit 2: Mkey<br\>bit 3: Open/private <br\>bit 4: Voice help wanted<br\>bit 5: Allowed to page absent user<br\>bit 6: Name extension available (AMC 08.02)<br\>bit 7: Door opening available<br\>bit 8: Station duplex control (AMC 08.02)<br\>bit 9-15 not used. bit 1 and 2 always 0 in AMC 06.00 | ||
10 | NET_OBJ_REF<br\>{ECL_STATION} | A-station technical reference: node and physical number<br\> | ||
11 | NET_OBJ_REF<br\>{ECL_USER} | A-station human reference: node and directory number. | ||
12 | TEXT16 | Asubscriber text (name) for display. | ||
13 | UINT1 | User Defined Properties (UDP) of Astation.<br\>Feature 1 = value 1, feature 8 = value 127, combinations allowed | AMC 07.10 | |
14 | NET_OBJ_REF | B number to be dialed in Bexchange.<br\>Only valid with remote functions 3 and 5<br\>If not used, this parameter should set to INVALID_NRF = 0x0F, or left out. | AMC 07.10 |