Difference between revisions of "MRBD - Relay Board"
From Zenitel Wiki
Line 1: | Line 1: | ||
+ | [[Image:MRBD.PNG|thumb|400px]] | ||
+ | |||
The '''MRBD''' relay board has six relays, which are controlled by [[RCO]]'s from the exchange or from a [[RIO]] unit. The MRBD must be powered by +24 VDC. The [[AlphaCom E7]] and [[AlphaCom E20|E20]] comes with a 24VDC outlet for such purpose, but in the [[AlphaCom E26]] a [[PDB|Power Distribution Board PDB]] is required. | The '''MRBD''' relay board has six relays, which are controlled by [[RCO]]'s from the exchange or from a [[RIO]] unit. The MRBD must be powered by +24 VDC. The [[AlphaCom E7]] and [[AlphaCom E20|E20]] comes with a 24VDC outlet for such purpose, but in the [[AlphaCom E26]] a [[PDB|Power Distribution Board PDB]] is required. | ||
Line 4: | Line 6: | ||
The MRBD board is supplied in an installation box that can be fastened onto the mounting rail on the connection field of the AlphaCom exchange, or mounted on the wall in any suitable position. | The MRBD board is supplied in an installation box that can be fastened onto the mounting rail on the connection field of the AlphaCom exchange, or mounted on the wall in any suitable position. | ||
+ | |||
[[Image:DoorOpening E7.jpg|thumb|Connection of MRBD in an AlphaCom E7]] | [[Image:DoorOpening E7.jpg|thumb|Connection of MRBD in an AlphaCom E7]] | ||
+ | |||
== Features == | == Features == | ||
* Equipped with 6 dual change over relays and relay drivers | * Equipped with 6 dual change over relays and relay drivers |
Revision as of 14:59, 10 February 2009
The MRBD relay board has six relays, which are controlled by RCO's from the exchange or from a RIO unit. The MRBD must be powered by +24 VDC. The AlphaCom E7 and E20 comes with a 24VDC outlet for such purpose, but in the AlphaCom E26 a Power Distribution Board PDB is required.
In the AlphaCom exchange it is recommended that all the RCOs be connected to the same ASLT board(s) in order to simplify cabling.
The MRBD board is supplied in an installation box that can be fastened onto the mounting rail on the connection field of the AlphaCom exchange, or mounted on the wall in any suitable position.
Features
- Equipped with 6 dual change over relays and relay drivers
- Powered by +24 VDC
- Connector for 6 RCOs + 2 GND reference signals
- Connects to the AlphaCom Subscriber Connection Board through a 1:1 cable
- Fastens onto mounting rail in AlphaCom exchange
Technical Specifications
Text | Value |
---|---|
Order Number | 1009970200 |
Input Voltage: Maximum Current: |
+24 VDC
60 mA (all relays active simultaneously) |
Relays | 6 relays each with 2 changeover contacts |
RCOs<br\><br\><br\> | Active high or low<br\>(switch setting on the board)<br\>high = AlphaCom<br\>low = TouchLine Compact |
Recommended room temperature<br\>(non-condensing) | 0'C to + 35'C<br\>+32'F to + 95' F |
Humidity Range: | 10% - 90% RH |
Dimensions: | 100 mm x 100 mm<br\>3.9" x3.9" |
Connector Types: | Spring terminals, AMP MTA 100 connector |
Connectors and Switches
The jumpers S1-S6 determine if the RCO should be activated by a high or low level. High level is used in AlphaCom system, while low level was used in the previous TouchLine generation of intercom system.