Revision as of 11:28, 19 November 2008
Using the $ST (Set_Timer) message. <br\> A number of stations should dial an Event Trigger number 9533 (feature 85) to pulse RCO 3 for 5 seconds. Assign the stations to UDP group 1.
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following events:
Event 1 - Start a 5 sec. timer when 9534 is dialled.
| Event Owner: | Stations w/ UDP Id: 1 |
| Event type: | 15 – Event Trigger |
| When change to: | ON or OFF |
| When related to: | Directory Number, Id: 9533 |
| Action: | RCO 3 ON |
| $ST L%1.dir w50 L%2.dir |
Event 2 - Cancel conversation when timeout.
| Event Owner: | Stations w/ UDP Id: 1 |
| Event type: | 21 - Event timeout |
| When change to: | ON |
| When related to: | Directory Number, Id: 9533 |
| Action: | RCO 3 OFF |