Difference between revisions of "Pulsing of RCO (Event Handler)"
From Zenitel Wiki
Line 5: | Line 5: | ||
In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following events: | In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following events: | ||
------------ | ------------ | ||
− | '''Event 1''' - Start a 5 sec. timer when | + | '''Event 1''' - Start a 5 sec. timer when 9533 is dialled. |
{| | {| | ||
|- | |- |
Revision as of 11:56, 7 June 2013
Using the $ST (Set_Timer) message. <br\> A number of stations should dial an Event Trigger number 9533 (feature 85) to pulse RCO 3 for 5 seconds. Assign the stations to UDP group 1.
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following events:
Event 1 - Start a 5 sec. timer when 9533 is dialled.
Event Owner: | Stations w/ UDP Id: 1 |
Event type: | 15 – Event Trigger |
When change to: | ON or OFF |
When related to: | Directory Number, Id: 9533 |
Action: | RCO 3 ON |
$ST L%1.dir w50 L%2.dir |
Event 2 - Cancel conversation when timeout.
Event Owner: | Stations w/ UDP Id: 1 |
Event type: | 21 - Event timeout |
When change to: | ON |
When related to: | Directory Number, Id: 9533 |
Action: | RCO 3 OFF |