− | A backup.bin file is compatible within the same [[AMC Database version]] only. It | + | A backup.bin file is compatible within the same [[AMC Database version]] only. It can be used to restore configuration between any AMC 10.2x version, but not between AMC 10.0x and AMC 10.2x, or between AMC 10.2x and 10.3x. |
When upgrading the AMC software and the AMC Database versions are different, the running intercom configuration will automatically be deleted and factory default settings will be generated. The settings done from AlphaWeb will be kept. | When upgrading the AMC software and the AMC Database versions are different, the running intercom configuration will automatically be deleted and factory default settings will be generated. The settings done from AlphaWeb will be kept. | ||
Revision as of 15:52, 4 January 2008
A Backup of the running configuration on the AMC-IP board can stored on a file in the flash memory. The file, called backup.bin, survives autoload. A backup can be done by:
- Backup from station: dialling 7820 (or 7821) + M-key on a SuperUser station
- Backup from AlphaWeb
Contents
Compatibility between AMC versions
A backup.bin file is compatible within the same AMC Database version only. It can be used to restore configuration between any AMC 10.2x version, but not between AMC 10.0x and AMC 10.2x, or between AMC 10.2x and 10.3x. When upgrading the AMC software and the AMC Database versions are different, the running intercom configuration will automatically be deleted and factory default settings will be generated. The settings done from AlphaWeb will be kept.
Always do a GetAll operation from AlphaPro before upgrading the AMC software
What is included in the backup?
The backup.bin file contains all system configuration, both settings done in AlphaPro and in AlphaWeb:
AlphaPro settings:
- Intercom configuration
AlphaWeb settings:
- Interface (IP addresses of Eth0 and Eth1)
- IP Routing
- Filter (firewall settings)
- Log configurations
- User management (User and password settings)
- Time and date (Timezone and NTP server setting)
- Hostnames
- RingMaster settings
License information is not stored in the backup.bin file
Backup from station
7820 Backup: A copy of the running configuration is stored in the backup.bin file. The backup is restored by dialling the Restore Backup code (7819 + M) on a SuperUser station.
7821 Master Backup: A copy of the running configuration is stored in the backup.bin file. The backup is automatically restored after exchange reset or power on. When using this backup option, a master backup (7821) should be made every time the configuration is changed, if not the changes are lost after next reset or power on.
Backup from AlphaWeb
A backup created from AlphaWeb is identical to the "7820 Backup". A "Master Backup" cannot be created from AlphaWeb.