Actions

Difference between revisions of "Increased volume on ringing signal"

From Zenitel Wiki

(Play a customized audio message during ringing)
Line 50: Line 50:
  
 
------------
 
------------
When a station starts to ring, alarm message number 3 will be played in the speaker. Alarm messages are using [[Volume and handset override|volume override]] by default, so the message will be played at maximum output level.
+
When a station is called and starts to ring, alarm message number 3 will be played in the speaker. The message will repeat it self until the call is answered, or the ringing times out. Alarm messages are using [[Volume and handset override|volume override]] by default, so the message will be played at maximum output level.
  
  

Revision as of 13:35, 12 March 2012

This article describes how to increase the volume of the private ringing signal, and set it back to normal when the call is answered (or canceled).

It also describes how a customized ringing signal can be played in the loudspeaker during the ringing sequence.


Increase volume on ringing signal

As from firmware version AMC 10.23 the volume to a station can be changed by the data command VOL. By using the event type 9 - Private Ringing mode in the Event Handler, one can set a higher volume during the ringing, and set it back to a normal level when the call is answered (i.e. when the Private Ringing mode goes off).

In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:


Event Owner: Stations w/ UDP, Id: 8 (all stations)
Event type: 09 - Private Ringing mode
When change to: ON or OFF
When related to: All
Action: $VOL L%1.dir U%chg(6,3)

When a station starts to ring the volume is set to level 6, and when the ringing stops the volume is set to level 3.


Play a customized audio message during ringing

The ringing signal must an audio file in wav format. The file must be uploaded to the AMC-IP as an alarm message. A basic or enhanced audio message license is required.

In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:


Event Owner: Stations w/ UDP, Id: 8 (all stations)
Event type: 09 - Private Ringing mode
When change to: ON or OFF
When related to: All
Action: AMS %1.phy %chg(3,0)

When a station is called and starts to ring, alarm message number 3 will be played in the speaker. The message will repeat it self until the call is answered, or the ringing times out. Alarm messages are using volume override by default, so the message will be played at maximum output level.