Difference between revisions of "TA-10"
From Zenitel Wiki
(→Configuration) |
|||
(12 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
− | {{ | + | {{AEIPS}} |
+ | '''TA-10''' is a Relay Module to be used with Turbine Industrial stations [[TFIE-1]] and [[TFIE-2]], and the Turbine kits [[TKIE-1]] and [[TKIE-2]]. | ||
[[File:1008140100.PNG|thumb|350px|The TA-10 Relay Module]] | [[File:1008140100.PNG|thumb|350px|The TA-10 Relay Module]] | ||
==Highlights== | ==Highlights== | ||
* Designed for use with Turbine Industrial stations TFIE-x, and the Turbine kits TKIE-x | * Designed for use with Turbine Industrial stations TFIE-x, and the Turbine kits TKIE-x | ||
− | * Fits inside the TFIE Industrial stations (Bracket included in the TFIE station) | + | * Fits inside the TFIE Industrial stations (Bracket is included in the TFIE station) |
* Dual high-power relays (DPDT) | * Dual high-power relays (DPDT) | ||
* Up to 400VAC /48 VDC per relay | * Up to 400VAC /48 VDC per relay | ||
− | * Up to | + | * Up to 8A current per relay |
* Heavy-duty spring-loaded terminals with spare grounding terminals | * Heavy-duty spring-loaded terminals with spare grounding terminals | ||
* Powered by Turbine Industrial stations (TFIE-x) or Turbine Extended Kit (TKIE-x) | * Powered by Turbine Industrial stations (TFIE-x) or Turbine Extended Kit (TKIE-x) | ||
Line 17: | Line 18: | ||
==Configuration== | ==Configuration== | ||
− | '''AlphaCom Mode''': | + | [[File:TA-10 RCO map.PNG|right|400px|thumb|Logical RCO 11 is mapped to the relay of the TA-10 unit on station 118]] |
+ | '''ICX-AlphaCom Mode''': | ||
* Use the [[AlphaPro]] tool, and go to '''Exchange & System''' > '''RCO''' | * Use the [[AlphaPro]] tool, and go to '''Exchange & System''' > '''RCO''' | ||
* The two relays must be mapped in the RCO table as pin 9 and pin 10 | * The two relays must be mapped in the RCO table as pin 9 and pin 10 | ||
Line 26: | Line 28: | ||
* Log on to the web interface of the station | * Log on to the web interface of the station | ||
* Select '''SIP Configuration''' > '''Relay Settings''', select '''Relay 3''' or '''Relay 4''', and configure which event should operate the relay | * Select '''SIP Configuration''' > '''Relay Settings''', select '''Relay 3''' or '''Relay 4''', and configure which event should operate the relay | ||
− | * See [[ | + | * See [[Relay_Settings_(SIP)|Relay Settings]] for more details |
==Dimensions== | ==Dimensions== |
Latest revision as of 13:41, 27 June 2023
TA-10 is a Relay Module to be used with Turbine Industrial stations TFIE-1 and TFIE-2, and the Turbine kits TKIE-1 and TKIE-2.
Highlights
- Designed for use with Turbine Industrial stations TFIE-x, and the Turbine kits TKIE-x
- Fits inside the TFIE Industrial stations (Bracket is included in the TFIE station)
- Dual high-power relays (DPDT)
- Up to 400VAC /48 VDC per relay
- Up to 8A current per relay
- Heavy-duty spring-loaded terminals with spare grounding terminals
- Powered by Turbine Industrial stations (TFIE-x) or Turbine Extended Kit (TKIE-x)
Connection
- Use the cable that comes with the TA-10, and connect one end to the Turbine Extended Board (Connector J2), and the other end to the TA-10 board as indicated in the drawing below
Configuration
ICX-AlphaCom Mode:
- Use the AlphaPro tool, and go to Exchange & System > RCO
- The two relays must be mapped in the RCO table as pin 9 and pin 10
- See RCO - Remote Control Output for more details
SIP or Pulse mode:
- Log on to the web interface of the station
- Select SIP Configuration > Relay Settings, select Relay 3 or Relay 4, and configure which event should operate the relay
- See Relay Settings for more details
Dimensions
- Dimensions (WxHxD): 100 x 50 x 40 mm
- Weight: 0.1 kg